background image

Detector is 

triggered 

Light 
turns on 

15 seconds 

Triggered 

180 

seconds 

Triggere 

is inoperable.) 

seconds). 

 

3.  Node ID is excluded. The device reverts to 

factory default state and will be in 
auto-inclusion mode for 4 minutes. 

2-second on, 2-second off 
For 2 minutes 

 

Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller. 

 
 
 
 

 

3. 

Lux Level 

 

 

Detected a 
movement 

 

 

Detected a 

movement 

(no response) 

 

 

Detected a 
movement 

Note

: If you are connecting this unit to a Z-Wave Controller that utilizes the S2 security protocol, you may 

be asked to enter a 5 digit Device Specific Key (DSK) that is unique to each unit by your controller. This 
can be found in one of two places: 
- on the QR code label on the back of the unit 
- on the insert card inside the packaging 

Table below lists typical problems encountered: 

The user can set a detecting percentage of lux level which determines when the light sensor will 
be activated.  If percentage of lux level of ambient illumination falls below this percentage, and a 
person moves  across  or  within the  protected  area,  the  detector  will  emit  Z-Wave ON  Command 
(i.e. Basic Set Command (Value = Basic Set Level)) to controller and activate connected modules 
and lighting.  Percentage can be set between 1% to 100%. 

 

Function 

Parameter Number 

Size 

Range 

Default 

Lux Level 

1~100 % 

20 

4. 

On-Off Duration 

The function of on-off duration setting will be useful if the detector is connected with a module or 
lighting.  The  duration  determines  how  long  the  module/lighting  should  stay  ON.  For  instance, 
Lamp Module turns off 100 secs after it has been turned on.  This parameter can be configured 
with the value of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds 
of delay. 

Function 

Parameter Number 

Size 

Range 

Default 

On-Off Duration 

5~3600(sec) 

15 

 

 
 
 
 
 

Troubleshooting 

 
 
 
 
 

 

Detected a 
movement 

 

 

Light 
turns off 

Specifications 

The table below lists the several steps involved when adding or removing the detector from the Z-Wave 
network. 

 

 

Specifications are subject to change without notice 
*measured at 10 triggers per day 

 

 

Federal Communication Commission Interference Statement 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation. 

 

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio 

Symptom 

Possible Cause 

Recommendation 

Cannot carry out inclusion and 
association 

1. 

Run out of battery power 

2. 

Check if reverse battery 
polarity 

3. 

Check if the detector is out 
of order 

1. 

Replace a new battery 

2. 

Refit the battery with 
correct polarity 

3. 

Ensure the detector is 
working properly 

Cannot control the connected 
modules 

1. 

Run out of battery power 

2.  Check if the detector is out 

of order 

1. 

Replace a new battery 

2. 

Ensure the detector is 
working properly 

The detector not working 

1. 

Run out of battery 
power 

2. 

Check if the mounting 
location is proper 

3. 

Check if the detector is 
mounted above a radiator 
or heater 

4. 

Check if the detector is out 
of order 

1. 

Replace a new battery 

2. 

Reposition its mounting 
location 

3. 

Remove the source of 
interference or 
reposition its mounting 
location 

4. 

Ensure the detector is 
working properly 

 

Battery 

CR123 3.0V 1700mAh Lithium Battery 

Battery Life 

1 year* 

Range 

Up to 100 meters line of sight 

Warm Up Time 

About 2 minutes 

PIR Detection Coverage 

Up to 10m x 110° (at 1.8m mounting height & 25°C) 

 

Operating Frequency 

EU:  868.42HMz 
US: 908.42 MHz 
JP: 922.5MHz 

FCC ID 

FU5SP817 

IC 

23210-SP817 

 

Action/Status 

Description 

LED indication 

No node ID 

The Z-Wave Controller does not allocate a node 
ID to the unit. 

2-second on, 2-second off 
For 2 minutes 

Auto Inclusion 

The power is applied for the first time and no node 
ID has been stored in the module, or after 
executing reset. 

 

 

Manual Inclusion 

1.  Put the Z-Wave Controller into 

inclusion mode. 

 

2.  Press the tamper switch 3 times within 1.5 

seconds to put the unit into inclusion mode. 

Exclusion 

1. Put the Z-Wave Controller into exclusion mode. 

 

2. Press the tamper switch 3 times within 1.5 

seconds to put the unit into exclusion mode. 

Factory Reset 
(This procedure 
should only be used 
when the controller 

1. Press the tamper switch 3 times within 1.5 

seconds to put the unit into exclusion mode. 

 

2.  Within 1 second of step 1, press the tamper 

switch again and hold until LED is off (about 5 

 

 