Mounting the Detector 

Choosing the location 

The PIR Detector is suitable for mounting in dry interior locations only. 

The recommended position for a PIR Detector is in the corner of a room mounted at a height between 1.8 
and 2m.  At this height, the detector will have a maximum range of up to 9m with a field of view of 110

°

subject to the position for the PCB being set in 5. (FIGURE 1&2) The position of the PCB inside the PIR 
can be set to 5 different positions to adjust the range of the  detector. Setting the PCB in position 3 will 
reduce  the  range  to  6m  approximately,  with  position  1  providing  a  range  of  3m  approximately.  The 
recommended position setting for the PCB is in position 5. 

 

 

2M 

Installation 

1. 

Carefully drill out the required mounting holes in the rear cover using 3mm drill according to whether 
the unit is being mounted in a corner or against a flat wall. 

Note: 

Using 1

st

 mounting hole to fulfill corner mounting installation, while 2

nd

 mounting hole for flat 

wall installation. (FIGURE 4a & 4b) 

 

 
 
 
 
 

Corner mounting 

 

13 12  11  10  9  8  7  6    5  4  3    2  1    0 

FIGURE 4a 

FIGURE 4b 

3. 

Using the rear cover as a template, mark the positions of the fixing holes on the wall. 

FIGURE 1 

 
 
 

 

PCB Position 

Range 

3m 

6m 

9m 

FIGURE 2 

When considering and deciding upon the mounting position for the detector the following points should 
be considered to ensure trouble free operation: 

1. 

Do not locate the detector facing a window or where it is exposed to or facing direct sunlight.  PIR 
Detectors are not suitable for use in conservatories. 

2. 

Do not locate the detector where it is exposed to ventilators. 

3. 

Do not locate the detector directly above a heat source, (e.g. fire, radiator, boiler, etc). 

4. 

Where possible, mount the detector in the corner of the room so that the logical path of an intruder 
would cut across the fan detection pattern.  PIR detectors respond more effectively to movement 
across the device than to movement directly towards it. (FIGURE 3) 

 

Less Sensitive   

More Sensitive 

FIGURE 3 

5.  Do not locate the detector in a position where it is subject to excessive vibration. 

6. 

Ensure that the position selected for the PIR detector is within effective range of the system, (refer 
to System Installation and Operating Manual). 

Note

: When the system is armed, household pets should not be allowed into an area protected by a 

PIR detector as their movement would trigger the PIR and generate an alarm. 

4. 

Fix the rear cover to the wall using the two 18mm No.4 screws and 25mm wall plugs, (a 5mm hole 
will be required for the wall plugs).  Do not over-tighten the fixing screws as this may distort or 
damage the cover. 

5. 

Configure the detector as described below.  Remember that on initial installation that the device 
needs to be tested. 

6. 

Check that the detector PCB is located and set in the correct position to provide the required 
detection range.  To adjust the PCB position, simply slide it up or down ensuring that the location 
legs are aligned with the required position number marked on the board. 

7. 

To refit the detector to the rear cover and locate the clips in the top edge into the rear cover.  Push 
the lower edge of the detector into place and refit the fixing screw in the bottom edge of the detector 
to secure in position.  Do not over-tighten the fixing screws as this may damage the casing. 

8. 

By walking into a protected area within coverage of 110 degrees, the detector will now be triggered 
each time the detector senses movement.  The associated appliances will be activated.  For 
example, siren will be sounded or indication of movement detection will be shown on the controller. 
It implies that the unit is working properly. 

Programming 

Z-Wave Group 

The detector supports either one of two Z-Wave Association Groups: 

Group 1

: Association with 1 Controller node. 

Group 2

: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting controllers). 

This  allows  the  detector  to  transfer  commands  directly  to  end  devices  without  the  participation  of  the 
controller. This has the effect that when the detector triggers, all devices associated with detector will be 
operated. 

Group 1 commands: 

  When  the  unit  is  powered  up  and  was  already  a  part  of  a  Z-Wave  network,  the  unit  will  send  a 

Notification Report to the node in Group 1. 

  When the detector senses a movement, the unit will send a Notification Report to the nodes of Group 

1. Once the movement is stopped, a Notification Report will be sent again to Group 1. 

  Upon detector status being changed, the unit will check its battery status simultaneously. When the 

battery level of the unit drops to an unacceptable level, the unit will emit Battery report to the nodes of 
Group 1. 

  When performing Factory Reset the unit will send Device Reset Locally Notification to the node of 

Group1. 