Group 2 commands: 

  When the detector is triggered, the unit will send BASIC_SET command which contains a value to 

the nodes of Group 2. 

Z-Wave Plus Info 

 

Role Type 

Node Type 

Installer Icon 

User Icon 

Slave Sleeping report 

Z-Wave Plus node 

Sensor Notification 
Device Type (Home 
Security) 

Sensor Notification 
Device Type (Home 
Security) 

Version 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

4.3D ( 6.71.01) 

 

Manufacturer 

Manufacturer  ID 

Product Type 

Product ID 

0x0060 

0x0001 

0x0006 

AGI (Association Group Information) Table 

Group 

Profile 

Command Class & Command (List) N bytes 

Group  Name(UTF-8) 

General 

Battery Report 
Notification Report 

Device Reset Locally Notification 

Lifeline 

Control 

Basic Set 

PIR Control 

Notification 

Event 

Type 

Event 

Event 
Parameters 

Length 

Event Parameters 

The power is applied for the first time 

0x08 

0x01 

0x00 

 

PIR Trigger ON 

0x07 

0x08 

0x00 

 

PIR Trigger OFF 

0x07 

0x00 

0x01 

0x08 

Tamper switch being press more than 10 
seconds 

0x07 

0x00 

0x01 

0x03 

Tamper switch being press more than 10 
seconds and released 

0x07 

0x03 

0x01 

 

Battery 

Battery Report (value) 

Description 

20

100 

Battery Level (%) 

0xFF 

Low Battery 

Command Classes 

The module supports Command Classes 

including… 

  COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

  COMMAND_CLASS_ASSOCIATION_V2

  COMMAND_CLASS_ASSOCIATION_GRP_INFO

  COMMAND_CLASS_TRANSPORT_SERVICE_V2 

  COMMAND_CLASS_VERSION_V2

  COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

  COMMAND_CLASS_DEVICE_RESET_LOCALLY

  COMMAND_CLASS_POWERLEVEL

  COMMAND_CLASS_SECURITY 

  COMMAND_CLASS_SECURITY_2 

  COMMAND_CLASS_SUPERVISION

  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

  COMMAND_CLASS_BATTERY

  COMMAND_CLASS_WAKE_UP_V2

  COMMAND_CLASS_NOTIFICATION_V4

  COMMAND_CLASS_CONFIGURATION

*Items marked an asterisk are secure command classes. 

Wakeup Command Class 

After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup 
Notification Command periodically at preset period to the controller. The Motion detector will stay awake 
for 10 seconds at least and then go back to sleep to conserve battery life. 

The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class 
based on the range values below: 

 

Minimum Wake Up Interval 

600s (10 minutes) 

Maximum Wake Up Interval 

86400s (1 day) 

Default Wake Up Interval 

14400s (4 hours) 

Wake Up Interval Step Seconds 

600s (10 minutes) 

 

Z-

Wave’s Configuration 

The  following  information  is  for someone that  has some  experience  in setting  up  a  Z-Wave  system or 
someone that has computer software running a Z-Wave controller.  Please get familiar with software of 
Z-Wave controller before getting started. 

To  save  power  consumption  for  the  battery,  RF  power  of  SP817  is  in  off  mode  ordinarily.  Pls  press 
Tamper switch once to on the RF power for 30 sec. in order to start function set up, and the user can see 
the LED start lighting up shortly every sec..  If set up is not finished within 30 sec., please press Tamper 
switch one more time to continue the set up. 

1-1  Basic Set Level 

When  Basic  Set  Command  is  sent  where  contains  a  value,  the  receiver  will  take  it  for 
consideration; for instance, if a lamp module is received the Basic Set command of which value is 
decisive as to how bright of dim level of lamp module shall be. 

Example: 
1-99: ON 

(Binary Switch Device) 

Dim Level    (Multilevel Switch Device) 

 

Function 

Parameter Number 

Size 

Range 

Default 

Basic Set level 

1 ~99 

99 

1. 

Sensitivity Level (PIR sensor only) 

In  order  to  provide  a  best  efficiency  of the  detector,  it is  recommended  to  test the  detector  with 
movements from a farthest end of the coverage area at first time of use.  If movements cannot be 
detected  sensitively,  simply  adjust  the  sensitivity  level  with  Configuration  Parameter  #3.  This 
parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 
means highest sensitivity. 

 

Function 

Parameter Number 

Size 

Range 

Default 

Sensitivity Level 

1~10 

2. 

Re-trigger Interval Setting (PIR sensor only) 

The Configuration parameter that can be used to adjust the interval of being re-triggered after the 
detector  has  been  triggered  as  Configuration  Parameter  #4.  No  response  will  be  made  during 
this  interval  if  a  movement  is  presented.  The  time  interval  can  be  set  between  5  secs  to  3600 
secs. 

 

Function 

Parameter Number 

Size 

Range 

Default 

Re-trigger Interval 

5~3600(sec) 

180 