43
Door Position Sensor (Door Encoder)
A public Inward Swinging door must use an I100 Door Position Indicator. If an I100
Door Position Indicator is not used for public doors that swing into the field of view of
the camera, erratic operation will result. The secure door does not require the use of
a Door Position Indicator. The cable for connecting the sensor should be extended
from the wall/frame and terminated into the unit. The cable is a straight through
Ethernet (cat 5) cable terminated with an RJ-45 connector. The other end of the
cable is then terminated as flying leads on the D portal connector as shown below.
Up to two door encoders can be installed on a single mantrap. When using a second
door encoder, terminate the leads on the portal C connector. In master/slave T-DAR
systems, wire door encoders to master control units only.
Public Door Encoder Connection
Annunciator Unit
The annunciator unit should be located at the security portal being monitored so that
violations are immediately announced to the violator as well as persons in the
secure area. The annunciator unit should be mounted less than 30m (100ft) from the
control unit. Install and terminate one Ethernet cable (straight through) on the
Annunciator Unit, leading directly to the ‘Annunc 1’ connector on the T-DAR control
unit. T-DAR mantraps use one annunciator. A master/slave T-DAR system will
require the annunciator be plugged into the master control unit. If the annunciator is
not turning on or is not playing the proper recordings, use the test buttons on the
“Advanced” tab to test the functionality. If the strobe and/or voices do not play using
the test buttons, check the CAT5 cable using a network tester (unplug cable before
testing). Warning: plugging in a camera head (CAT5 cable) into an annunciator port
will damage the camera head.
Summary of Contents for T-DAR T1010MT
Page 16: ...9 Figure 2 T DAR Control Unit CAD ...
Page 18: ...11 Figure 4 T DAR Annunciator CAD ...
Page 20: ...13 Figure 6 T DAR Stereo Tracking Head ...
Page 22: ...15 FFigure 8 T DAR Door Encoder ...
Page 24: ...17 Figure 12a T DAR Camera Cable Extender Amplifier CAD ...
Page 26: ...19 Figure 13 T DAR Annunciator Encoder Cable Extender CAD ...
Page 28: ...21 WMK 100 Camera Head Wall Mount Figure 15a WMK 100 Camera Head Wall Mount ...
Page 29: ...22 CMK 100 Camera Head Ceiling Mount 15b CMK 100 Camera Head Ceiling Mount ...
Page 97: ...90 Control Unit Panel Connections Figure 35 Control Unit Connections Front Panel Upper Panel ...
Page 108: ...101 ...