63
Input and Relay Output Screen of the Monitor Display
The “Show I/O” option of video outputs will display a real-time view of the T-DAR
status. Green squares represent output relays that are closed. There are two door
lock relays (1 and 2) as well as two alarm output relays (5 and 6). It is normal for
output relay 1 to stay on. A green relay square will always represent a locked door;
there is no option to invert a relay’s status. To invert a relay output, an external relay
must be used. Relays 3, 4, 7, and 8 will not be used and none of the outputs 1-12
will be used in this mantrap. Viewing the
“Show I/O” display is only available from
the master of a master/slave system.
Inputs
The inputs of the T-DAR, control its operation and place it in various states. The
mantrap will not work if the inputs are not signaled correctly. Green inputs (4 and 6)
will always represent closed doors. These signals can be inverted in the GUI, using
an open circuit or closed circuit to signal the T-DAR that a door is closed (green box
= closed). The Secure and Public Grant signals can be inverted in the GUI as well. A
green box public or secure grant will always signify a valid grant.
Show I/O Display of T-DAR Video Out
Summary of Contents for T-DAR T1010MT
Page 16: ...9 Figure 2 T DAR Control Unit CAD ...
Page 18: ...11 Figure 4 T DAR Annunciator CAD ...
Page 20: ...13 Figure 6 T DAR Stereo Tracking Head ...
Page 22: ...15 FFigure 8 T DAR Door Encoder ...
Page 24: ...17 Figure 12a T DAR Camera Cable Extender Amplifier CAD ...
Page 26: ...19 Figure 13 T DAR Annunciator Encoder Cable Extender CAD ...
Page 28: ...21 WMK 100 Camera Head Wall Mount Figure 15a WMK 100 Camera Head Wall Mount ...
Page 29: ...22 CMK 100 Camera Head Ceiling Mount 15b CMK 100 Camera Head Ceiling Mount ...
Page 97: ...90 Control Unit Panel Connections Figure 35 Control Unit Connections Front Panel Upper Panel ...
Page 108: ...101 ...