                PROPERTY 

 

RED AND GREEN LIGHTS

 

ADJUSTING  THE  THERMOSTAT

 

Factory temperature pre-set

 

is 190°F

+

-

(88°C) ±5°. To reset the 

thermostat to that setting, turn

 

the indicator two notches

 

to the right of vertical. 

MIN  

MAX

 

Adjust the thermostat  

approx. 194°

 

slowly, turning the dial

 

clockwise to increase temperature or 
counter clockwise to decrease 
temperature, then activate water 
dispenser handle for 20 seconds to 
bring in fresh water to be heated at the 
new setting. Allow 5-7 minutes for 
water to reach new temperature.

 

 

Scalding Hazard: Do not allow 

water to boil. May result in 

severe burns.

 

 

 

Poor water flow: 

 

• The tank is not under pressure 

which may cause a slight delay 
in water flow. This is a safety 
feature. 

  •  Make sure all valves on water supply are open. 

•  Check hose from water dispenser for twisting or tight  bending. 
•  Check if quick-connect filter screen or water dispenser filter screen is clogged 

(see water dispenser manual). Clean if necessary. 

Water boils or 
vapor appears: 

• The thermostat may be set too 

high. 

• Lower temperature setting by turning thermostat control counterclockwise. 

 

Hot water drips or 
sputters from 
faucet: 

 

• The thermostat may be set too 

high. 

 

• Turn the thermostat control dial counterclockwise to reduce the temperature. 
•  Ensure that the hose connecting the water dispenser to the hot tank is not 

clogged, twisted or kinked. 

•  Check for a clogged filter screen in the quick-connect fitting (see 

CLEANING  THE QUICK CONNECT FILTER SCREEN instructions 
above). 

•  Check for proper installation of  tubing from water dispenser to hot water 

tank and water dispenser to water line. If connected backwards or cross-
connected, valve may be damaged. 

 

Electric Shock Hazard: To prevent electrical shock, disconnect power before          

 

servicing unit. Use only a properly grounded and polarized electric outlet.

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 
 

 
 

 
 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 
 
 
 
 
 
 
 
 
 

Regularly

 inspect the unit for any signs of leakage. If 

there are signs of water damage, immediately remove 
the unit from service. 

To avoid water damage from leakage, replace all cut, 
loose or split tubing. 

A drain 

pan, plumbed to an appropriate drain or 

outfitted with a leak detector, should be used in those 
applications where any leakage could cause property 
damage.

 

The Green light indicates

 

hot water is 

available.  
The Red Light indicates water is heating in 
the tank.

 

Only use mild cleaners to clean the water 
dispenser and plastic components.  
Cleaners with acids, abrasives, alkaline or 
organic solvents will

 

result in deterioration of the 

plastic

 

components and void the warranty.

 

CLEANING  THE  WATER DISPENSER AND  TANK

 

TROUBLESHOOTING

 

PROBLEM          POSSIBLE CAUSE                    WHAT TO DO

 

CARE AND USE

 

Summary of Contents for 5-036

Page 1: ...rence Proof of purchase is required for Warranty Staple receipt or proof of purchase to this manual for easy reference Warranty is non transferable NOTE Do not plug appliance into the power supply if...

Page 2: ...should not be confused with a defective product Lab tests have confirmed that during the heat up cycle it is possible that up to 5 ounces of water may leak from the spout for up to 15 minutes after t...

Page 3: ...ession fitting for water tank outlet Supplied with your Newport Brass water dispenser Fitting 3 PRESSURE FREE HOT WATER DISPENSER DESIGN Unlike other types of household water heaters this tank is not...

Page 4: ...le vapors and liquids in the vicinity of this or any other appliance Property Damage To avoid water damage replace any loose or split tubing Periodically inspect the unit for any signs of leakage and...

Page 5: ...nser be provided Note Use an outlet that cannot be turned on off by a switch If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in o...

Page 6: ...enser outlet tube red color hose to the rear water connection inlet at the top corner of the tank Push the tube straight into the quick connect fitting as far as possible for both connections Reattach...

Page 7: ...lugging the power cord into an electrical outlet If the tank is empty and the thermostat is set to the ON position when the power cord is connected the self resetting fuse will disconnect the current...

Page 8: ...er screen if you experience a reduction in water flow 1 Unplug the tank from the power supply 2 Turn the thermostat control dial to the OFF position rotate counter clockwise 3 Remove the quick connect...

Page 9: ...counterclockwise to reduce the temperature Ensure that the hose connecting the water dispenser to the hot tank is not clogged twisted or kinked Check for a clogged filter screen in the quick connect f...

Page 10: ...oils turn thermostat control dial slightly counterclockwise until the gurgling and or sputtering stops This should take place within 20 seconds Turn control dial an additional 1 8 3 mm counterclockwis...

Reviews: