NewMar PM-12-40 Installation & Operation Manual Download Page 2

P.O. Box 1306, Newport Beach, California 92663  •  Phone: 714-751-0488  •  Fax: 714-957-1621  •  E-Mail: [email protected]

www.newmartelecom.com

2

Quick Reference Contents

The front and rear panel features of the Power Modules are illustrated below, along with the page number where information on each 

particular feature is located.

FIGURE 2: Power Module Rear Panel (560 watt models only):

FIGURE 3: Power Module Rear Panel (1,000 watt models & PM-12-45 only):

FIGURE 1: Power Module Front Panel (all models): 

Cooling Fans, 

Page 7 

Output Voltage 

Adjustment Pot, 

Pages 7, 8 

Output Voltage 

T est Points, 

Page 7 

PM "ON' 

Indicator LED, 

Page 7 

Input Switch/ 

Circuit Breaker, 

Page 7 

a.c. Input Socket, 

Page 4 

Output Terminals, 

Page 5 

Wiring Access Port, 

Page 8 

Remote Alarm Contacts, 

Page 8 

Chassis Grounding Stud, 

Page 6 

a.c. Wiring Strain Relief, 

Page 4 

Chassis Grounding Stud, 

Page 6 

Remote Alarm Contacts, 

Page 8 

Wiring Access Port, 

Page 8 

Output Terminals, 

Page 5 

a.c. Input Wiring 

Compartment, 

Page 4 

Summary of Contents for PM-12-40

Page 1: ...ther Factors 3 III INSTALLATION 3 A Materials Provided 4 B Mounting 4 C AC Input Wiring and Voltage Selection 4 D DC Output Wiring 5 E Parallel Wiring 6 F Chassis Grounding 6 IV OPERATION 7 A AC Input...

Page 2: ...FIGURE 3 Power Module Rear Panel 1 000 watt models PM 12 45 only FIGURE 1 Power Module Front Panel all models Cooling Fans Page 7 Output Voltage Adjustment Pot Pages 7 8 Output Voltage Test Points Pa...

Page 3: ...of miles from the strike point Equipment generated transient sources include utility fault conditions and load switching as well as on site equipment such as pumps and air conditioning loads motors ph...

Page 4: ...d Blue AC Neutral Green AC Ground safety earth may be Green with Yellow Stripe Input Voltage Selection As shipped from the factory the PM is set up for 230V AC input For 115V AC applications set the r...

Page 5: ...instead if the application requires it see V2 below V OUT Terminal This output is routed through an internal or ing isolation diode This terminal should be used for most installations Use of this ter...

Page 6: ...output voltage 4 Shut off the PM turn on the next unit in the system and repeat steps 2 through 4 until all PM s in the system have the identical V OUT output voltage Method 2 1 With all Power Modules...

Page 7: ...g circuit of the PM should prevent these fuses from blowing under normal operating conditions If the d c fuse s blow this may indicate a reverse polarity hook up or an internal short Always disconnect...

Page 8: ...0V DC V Options Available from the Factory A Charger Function Board Installed on Model PM 12 45 The PM can be factory modified with the installation of a charger function board If the PM has already b...

Page 9: ...out of modules for repair or replacement The kit consists of two wiring harness one for positive and negative DC output wiring another for alarm contact wiring Wires are pre cut to proper length all n...

Page 10: ...n If breaker continues to trip contact factory 2 Return to place of purchase for repair re placement or contact NEWMAR for return authorization Replace output fuse If fuse blows again return to place...