TEST / TROUBLESHOOTING

Refer to the status LED indicator legend on page 5, which provides diagnostics of what stage the MDP is currently 

operating. 

1) Testing Battery Back-up Function:

    With a load connected to MDP output remove input fuse and confirm load is powered without interruption from  MDP    

  internal battery: The two GREEN LED’s (“CHARGING” & “INPUT CONNECTED”) should extinguish and the  AMBER “Back-   

  up Power” LED will illuminate.

2) Start-up:

    When connecting or reconnecting input power to the MDP it is normal for the “INPUT CONNECTED” LED & “BACK- UP  

 

  POWER” LED to both illimunate for 2-3 seconds.

3) Charging LED:

   

a)

 It is normal for the CHARGING LED to extinguish when the three stage charger goes in to sleep mode. (Sleep mode     

    reduces MDP input current draw when the internal battery is full charged.)

   b) 

If fuses blow repeatedly, this usually indicates a shorted component. Contact NEWMAR for further trouble shooting 

    advice. Always verify that the replaced fuses are of the correct rating. Use standard ATC fuses. Do no use 

  slow-blow fuses.

   

c)

 Flashing Red LED - internal charging temperature exceeds 50° C.

FACTORY CONTACT INFORMATION

If a problem persists after you have applied the above-outlined solutions, or if you have any questions about the 

installation and proper operation of the MDP-25.0, please contact NEWMAR’s Technical Services Manager:

Phone: 

714-751-0488 - From the hours of 7:00 A.M. to 4:30 P.M. weekdays, P.S.T.

Fax:

 714-957-1621 

Email:

 [email protected] 

We are happy to consult with you to resolve any problems or questions you may have. If during consultation, it 

appears the MDP-25.0 must be returned to the factory for repair we will issue a Return Materials Authorization at that time.

SPECIFICATIONS:

INPUT:

 Stand-by:12 VDC, 12.2 ->15.5 VDC, 11.5 minimum input required for start up,                                                                                                                                              

            Maximum Input Current: 28.5 Amps (25 Amps max. Load + 3.5 Amps Charger)

            Stand-by Current: <40 mA (no load on output, internal battery charged, 3 Stage charger in sleep mode)

           

OUTPUT:

 12 VDC Filtered, Voltage Spike Protected with Back-Up Battery 25 amps Max.

          

BACK-UP POWER: 

12.0 VDC Nominal, from 7 AH internal battery:

 

                 5 amps for 60 Minutes

 

                 10 amps for twenty Minutes

 

                 25 amps for six Minutes 

(All the above assuming fully charged battery @ 25° C)    

                                                                          

BATTERY:

 Sealed Lead Acid, Rechargeable 7.0 AH, 5 Years Typical Life - User Replaceable

INTERNAL CHARGER: 

2 Amps, 3 Stage, Temperature Compensated

FILTERING:

 Audio through 200 MHz

VOLTAGE SPIKE PROTECTION: 

Transient Energy Capability; 100 Joules, 4,000 amps Max

OPERATING TEMPERATURE: 

0 - 50° C

SIZE/WEIGHT:

 5.75” H x 6.0” W x 8.5” D (14.6 x 15.24 x 51.59 cm) / 9.4 lbs. (4.3 kg)

Summary of Contents for MDP-25.0

Page 1: ...Materials Provided 3 Installation 3 Mechanical Power Wiring Signal Wiring Motorola Output Settings Default and Optional Operation 4 Status LEDs Disconnect Timer TMR Operation Advanced Settings Backup...

Page 2: ...Fax 714 957 1621 E Mail techservice newmarpower com www newmartelecom com Quick Reference Guide Status LEDs Page 5 Status LED Legend Page 5 D Sub 9 Pin Motorola Interface Page 4 Input Output Wiring P...

Page 3: ...engine is off Allows use of accessory loads per programmed time limit user adjustable while preserving battery for emergency starting Factory default is not active see page 5 Built in LVD Low Voltage...

Page 4: ...nput wires by disconnecting the battery or shutting off the appropriate circuit Note the MDP functions as an uninterruptable power source If electronics are wired directly to the MDP output and the pr...

Page 5: ...on of voltage occurs augmenting voltage to the electronics for 3 seconds If proper primary voltage is not restored within the 3 second time frame input from the vehicle battery disconnects and electro...

Page 6: ...nce the battery voltage reaches approximately 14 2 volts the charging current will start to reduce The voltage will remain at 14 2 volts stage 2 high rate absorption charge until the current to the ba...

Page 7: ...s 5 Note that the TMR feature is disabled if the Ignition IN pin Pin 2 of the D sub 9 pin connector on front panel see Figure 2 is connected to a voltage greater than 2 volts i e battery Back up funct...

Page 8: ...internal battery see table 4 Hysteresis should be set after determined the amount of voltage drop from the DC source vehicle battery to input terminals of the MDP when the intended output load curren...

Page 9: ...battery loosen and back out the four front Battery Access Plate securing screws and remove Battery Access Plate Once the plate is removed you will see the battery is secured in position by a Locking...

Page 10: ...N If a problem persists after you have applied the above outlined solutions or if you have any questions about the installation and proper operation of the MDP 25 0 please contact NEWMAR s Technical S...

Page 11: ...Box 1306 Newport Beach California 92663 Phone 714 751 0488 Fax 714 957 1621 E Mail techservice newmarpower com www newmartelecom com DIMENSIONAL DRAWINGS 6 980 8 460 5 400 4 750 300 6 000 281 x 4 5 79...