5:6
2011
Dutch Star Diesel Pusher
by Newmar
Ground Fault Circuit Interrupt Receptacles
The 120 volt electrical outlets in the kitchen and bath area are ground fault circuit interrupt (GFCI) protected
receptacles. The electrical outlets located in the slide out are wired through the kitchen GFCI. The exterior
electrical outlets are wired through the bathroom GFCI. If an item plugged into a slide out or outside receptacle is
not working, check for a tripped GFCI in the kitchen or bathroom. These outlets protect the user from ground
faults between a hot wire and ground. The GFCI will not reduce the shock hazard if the short is between a neutral
and hot wire or two hot load wires.
The GFCI should be tested at least once a month. The 120 volt electrical system must be on in order to test the
GFCI. The reset button needs to be pushed in all of the way before starting the test. Push the test button. This will
cause the reset button to pop out which means that the protected circuits have been disconnected. Push the reset
button back in until a click is heard. This will reactivate the protected circuit. If the GFCI is working properly the
reset button will remain in the “IN” position.
ICC Flasher
On the dash you may have a switch labeled “ICC Flasher.” This switch is a momentary type of switch. This
means it is only active while the switch is being pressed. It enables the driver to communicate with other traffic by
flashing the clearance and side lights of the coach. If the lights are on, it will turn them off. If the lights are off, it
will turn them on.
Inverter/Converter (Optional)
When 120 volt power is not available, either from the power cord or the
generator, the optional inverter/converter may be used, if installed. The
control panel for the inverter is located above or near the entrance door. Once
turned on, the inverter transforms 12 volt power to 120 volt power for the
operation of lights, appliances, televisions, etc. The 120 volt power that is
generated from the inverter is routed to the electrical sub-panel located next to
the main breaker box in cabinet above the bed.
The breakers in the sub-panel are labeled to explain where the 120 volt power
is routed. It generally supplies power to the microwave, kitchen, bath, and selected receptacles. The inverter is
equipped with an automatic transfer switch. This allows automatic switching from inverter to converter. When
you are connected to an outside power source or running the generator, the converter (in the inverter) will
automatically switch on to charge the 12 volt batteries. For more detailed information consult the manufacturer
Owner’
s Manual located in the Owner Information Package.
Generator
The generator is located in a compartment in front of the motorhome. It is mounted on slides for easy access. The
slides for the generator must be unlocked before free movement is allowed. Prior to starting or stopping the
generator, make sure all of the 120 volt appliances are turned off. After the generator has started, wait until the
transfer switch has connected before turning on any of the appliances. The generator can be started from either the
remote start switch located on the dash or directly at the generator itself. The hour meter installed on the generator
calculates the number of running hours of the generator motor. This is used for maintenance schedules. If your
coach contains an Energy Management System, 8kw generator, and three roof air conditioners, the combined load
may exceed the capabilities of the generator. Please remember to turn off one of the air conditioners as the 8kw
generator is not intended to run all three roof air conditioners at the same time.
Summary of Contents for Dutch Star 2011
Page 1: ...OWNER S GUIDE...
Page 5: ...1 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 10: ...2 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 23: ...3 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 35: ...4 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 40: ...5 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 47: ...6 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 55: ...7 2 2011 Dutch Star Diesel Pusher by Newmar...
Page 64: ...8 2 2011 Dutch Star Diesel Pusher by Newmar...