16
APPLY EXTERNAL
AC POWER
30 SECOND DELAY
START BULK CHARGING
START 12 HOUR TIMER
12 HOURS ELAPSED?
4 HOURS ELAPSE,
TURN CHARGER OFF
YES
YES
DC LOAD ON BATTERY
CAUSES VOLTAGE TO
DROP BELOW:
12.5 VDC (12 VOLT MODELS)
25.0 VDC (24 VOLT MODEL)
33.3 VDC (32 VOLT MODEL)
START FLOAT MODE*:
13.2 VDC (12 VOLT MODELS)
26.4 VDC (24 VOLT MODEL)
35.2 VDC (32 VOLT MODEL)
START 4 HOUR TIMER
SATISFACTORY
GAS POINT DETECTION
TESTS?
BATTERY
ACCEPTS MORE THAN
20 AMPS?
(APPROX.)
NO
NO
FIGURE 5: Charger Operation and L.E.D. Indication Flow Chart
NO
YES
* Note: Three stage charge cycle
resumes (goes to top of chart)
each time external AC is
removed then reapplied.
STOP 12 HOUR TIMER,
START ABSORPTION STAGE,
START 4 HOUR TIMER
TURN CHARGER OFF
Status Panel Indications
= L.E.D. Illuminated
= L.E.D. Not Illuminated