B) Charger Output Selector
The ideal charge regimen for gel-cell and flooded (wet) lead-acid or AGM (Absorbed Glass
Mat) batteries differs somewhat. Gelled electrolyte may be lost or damaged by high voltage
and, once lost, cannot be replaced as it can with a wet lead acid battery. (The charge regimen
recommended for AGM batteries is typically similar to that of flooded lead-acid batteries.)
Consequently, the charger is equipped with a switch for selecting the proper charge voltage,
based on battery type.
The Charger Output Selector is a recessed selector switch also located on the right-hand side
of the unit, near the rear, beside the Battery Capacity selector. There are four positions on
this selector;
only
positions C or D (depending on battery type) are used for normal charger
operation. (The A and B positions are used for a special equalization output, which is dis-
cussed shortly.)
Verify the type of batteries being used, then use a small flat-tip screwdriver to place the
selector into the correct position according to the following chart (this information is also
duplicated on the unit beside the selector port).
Note:
Mixing of battery types such as gel-cell
and flooded on the output of the charger is
not
recommended, even if output is split among
multiple banks with an isolator or integrator:
Charger Output Selection Chart: 12 Volt Models
Switch
Output Voltage (VDC)
Position
Use For
@ Charge
@ Float
A
Equalization
CAUTION
15.2
13.2
B
Equalization
CAUTION
14.6
13.2
C
Flooded/AGM Charging
14.2
13.2
D
Gel-Cell Charging
13.8
13.2
Charger Output Selection Chart: 24 Volt Models
Switch
Output Voltage (VDC)
Position
Use For
@ Charge
@ Float
A
Equalization
CAUTION
30.4
26.4
B
Equalization
CAUTION
29.2
26.4
C
Flooded/AGM Charging
28.4
26.4
D
Gel-Cell Charging
27.6
26.4
Charger Output Selection Chart: 32 Volt Models
Switch
Output Voltage (VDC)
Position
Use For
@ Charge
@ Float
A
Equalization
CAUTION
40.7
35.2
B
Equalization
CAUTION
39.2
35.2
C
Flooded/AGM Charging
37.9
35.2
D
Gel-Cell Charging
36.8
35.2