Contact your local building authority regarding restrictions and installation requirements.
Walls protection
Note: The side load door must not be used in corner installations if this product is a side load door
version.
Distance to wall made of combustible material
See figure 2 & refer to building regulations & any other rules in force, including BS
8303 and BS EN 15287-1:2007.
Distance to walls covered by a firewall
See figure 2 & refer to building regulations & any other rules in force, including BS
8303 and BS EN 15287-1:2007.
Firewall requirement.
Refer to building regulations & any other rules in force, including BS 8303 and BS EN
15287-1:2007.
The firewall must be at least
100 mm thick
and be made of brick, concrete-stone or light concrete.
Other materials and structures with satisfactory documentation may also be used.
Note: When installing this stove into a non combustible chimney or non combustible wall, providing
all surrounding non combustible walls have a minimum thickness of 200mm the clearance between the
rear & sides of stove can be reduced to 50mm, refer to building regulations & any rules in force.
However it is recommended that the measurement between the sides & rear of stove to be as large as
possible above this dimension, as the efficiency of this stove is dependent on the clearances as shown
in figure 2.
Ceiling protection.
Refer to building regulations & any other rules in force, including BS 8303 and BS EN
15287-1:2007.
There must be a minimum distance of
1200 mm
to any combustible ceiling above the fireplace.