Smokes
when
lighting up.
Flue duct is cold.
Room
decompression
Burn paper and
kindling wood to
increase heat.
In houses equipped
with mechanical
ventilation, open a
window until the fire
is well established.
Smokes
while
burning.
Ventilation
insufficient
Down draught.
Room
decompression
Consult a chimney
specialist.
Check that the flue is
not obstructed,
sweep if necessary.
Install an anti-down
draught cowl.
Consult your Dealer.
In houses equipped
with Mechanical
Ventilation, an
outside air intake
must be installed for
the chimney.
Low heat output.
Incorrect Fuels.
Use fuel
Recommended.
3.5 Replacement parts
Only use replacement parts recommended by the manufacturer.
Modifications to this appliance
must not
be made.