Page 7

Raymor Showers / Pivot Door Set

ALLOW 24 HOURS FOR 

SILICONE TO DRY BEFORE 

USE

A

B

STEP 3
1.  Slide Door assembly and Return panel into the wall channels. (1) 
2.  Bring together the two panel assemblies together at the corner (2).  
3.  Adjust the Door and Return Panels evenly on the tray and into the Wall channels (1).
4.  Bring the corner joint together and drill and fasten this point (2).
5.  Align the door frame and return panel evenly to the walls and Tray. 
6.  Square up the door frame. 
7.  Fit door inserting top rollers into top rail and push down bottom rollers into bottom rail.
8.  Make final alignment adjustments to the Shower with a spirit level and fasten frame to 

Wall channels 

STEP 4
1.  Fasten the handle in place (A). 
2.  Apply silicone to the outer boundaries as indicated with dotted lines (B).

Note: Sealing on the inside of the shower will void the warranty.

Summary of Contents for Raymor RAY1200CHR

Page 1: ...PRODUCT CODES RAY1200CHR RAY1200WHT INSTRUCTION MANUAL VERSION 16 0001 Newline Group Limited Freephone 0508 639 5463 www newline co nz SLIDING DOOR SET INSTRUCTION MANUAL...

Page 2: ...INSTRUCTIONS BEFORE INSTALLATION AND USE CONTENTS PAGE Important Information 1 Preparation Checklist 2 Supplied Components 3 Layout Procedure 5 Installation Steps 6 Newline Group Limited Freephone 05...

Page 3: ...ill chip and destroy the glass panel Installation Glass panels and assemblies are heavy Two man lifting is recommended for handling and installation Determine positioning of wiring and piping within w...

Page 4: ...specific detailing of framing or plasterboard lining This will need to be competed prior to framing Shower waste and supply fittings must be installed by a registered plumber TILE INSTALLATION OPTION...

Page 5: ...ll Posts 2 2 Screws M4x3 8 PACK 2 3 Screw Cover Caps PACK 12 4 Screws M4x1 3 8 PACK 16 5 Screws M4x5 16 PACK 12 6 Spacer Blocks 2 7 Return Panel 1 8 Handle Set 1 9 Top Rollers 2 10 Water Deflectors 2...

Page 6: ...of plumb up to 8mm Greater variances to plumb than 8mm at the wall must be assessed and adjusted because this impacts on the boundary line Preferably the door and return panel boundary line remains e...

Page 7: ...t Plan Page 5 set up and plumb Wall Channels on boundary line 2 Apply silicone to back of wall channels and fasten to the wall ensuring that they remain plumb Tiling Note Some authorities do not allow...

Page 8: ...17 Spacer Blocks 6 4 x 35mm screws 3 Two spacer Blocks 6 Two Glass clamps 16 and 2 screws 4 x1 0mm Note Refer back to Assembly Drawing on page XX to reference numbers 1 Bring the Door Frame together a...

Page 9: ...orner joint together and drill and fasten this point 2 5 Align the door frame and return panel evenly to the walls and Tray 6 Square up the door frame 7 Fit door inserting top rollers into top rail an...

Page 10: ...nd using GIB Aqualine 13mm or equivalent for both sides of the Alcove This is optimum width Measure outside boundary line at 15mm in from the outside of the Tray Mark the tray and plumb up the walls P...

Page 11: ...terproof layer to be penetrated Use Bostik V60 to fix Wall Channels and allow to cure as per manufacturers instructions STEP 2 Assembly of Door Frame Components Top and bottom rails 13 Fixed front pan...

Page 12: ...ite wall channel and fasten at the boundary line 4 Even out the door frame within each wall channel 5 Square up the door frame and door 6 Fit door inserting top rollers into top rail and push down bot...