Programming with Serial Commands
A data format can also be created by serial commands (HEX) sent from the host device.
All commands must be entered
in uppercase letters
.
The syntax consists of the following elements:
Prefix:
“~<SOH>0000” (HEX:
7E 01 30 30 30 30
), 6 characters.
Storage type:
“
@
” (HEX:
40
) or “#” (HEX:
23
), 1 character. “
@
” means permanent setting which will not be lost by
removing power from the scanner or rebooting it; “#” means temporary setting which will be lost by removing power from
the scanner or rebooting it.
Add Data Format Command:
“DFMADD” (HEX:
44 46 4D 41 44 44
), 6 characters.
Data format label:
“0” (HEX:
30
) or “1” (HEX:
31
) or “2” (HEX:
32
) or ”3” (HEX:
33
), 1 character. “0”, “1”, “2” and “3”
represent Format_0, Format_1, Format_2 and Format_3 respectively.
Formatter command type:
“6” (HEX:
36
), 1 character.
Interface type:
“999” (HEX:
39
39
39
), 3 characters.
Symbology ID Number:
The ID number of the symbology to which you want to apply the data format, 3 characters. 999
indicates all symbologies.
Data length:
The length of data that will be acceptable for this symbology, 4 characters. 9999 indicates all lengths. For
example, 32 characters should be entered as 0032.
Formatter commands:
The command string used to edit data. For more information, see the “Formatter Command Type
6” section in this chapter.
Suffix:
“;<ETX>” (HEX:
3B
03
), 2 characters.
Example:
Program a Format_0 data format using formatter command type 6, Code 128 containing 10 characters
applicable, send all characters followed by “A”.
Enter:
7E 01 30 30 30 30 40 44 46 4D 41 44 44 30 36 39 39 39 30 30 33 39 39 39 39 46 31 34 31 3B 03
(~<SOH>0000@DFMADD069990020010F141;<ETX>)
Response:
02 01 30 30 30 30 40 44 46 4D 41 44 44 30 36 39 39 39 30 30 33 39 39 39 39 46 31 34 31 06 3B 03
(<STX><SOH>0000@DFMADD069990020010F141<ACK>;<ETX>)
When creating multiple data formats sharing a label, the formats are separated from each other by a vertical bar (|) in the
serial command.
Example:
~<SOH>0000@DFMADD069990020010F141|069990039999F142|069990049999F143;<ETX>
Summary of Contents for NLS-HR32 Series
Page 1: ...NLS HR32 Hand held Barcode Scanner User Guide...
Page 3: ...Revision History Version Description Date V1 0 0 Initial release December 4 2016...
Page 21: ...Dimensions of the Scanner unit mm 5...
Page 23: ...Dimensions of the Cradle unit mm 7...
Page 83: ...Enter Setup 67 Exit Setup Norway Poland Portugal Romania Russia Slovakia Spain Sweden...
Page 84: ...Enter Setup Exit Setup 68 Switzerland German Turkey_F Turkey_Q UK Japan...
Page 97: ...Enter Setup 81 Exit Setup 8ms 9ms 10ms...
Page 134: ...Enter Setup Exit Setup 118 40ms 45ms 50ms 55ms 60ms 65ms 70ms 75ms...
Page 136: ...Enter Setup Exit Setup 120 500ms 600ms 700ms 800ms 900ms...
Page 167: ...Enter Setup 151 Exit Setup Set ISBN Format ISBN 10 ISBN 13...
Page 200: ...Enter Setup Exit Setup 184 QR ECI Output Disable QR ECI Output Enable QR ECI Output...
Page 206: ...Enter Setup Exit Setup 190 Set the Number of Barcodes 1 2 3 4 5 6 7 8...
Page 276: ...Appendix Digit Barcodes 0 9 0 1 2 3 4 5...
Page 277: ...6 7 8 9...
Page 278: ...A F A B C D E F...
Page 299: ...Unicode Key Maps 104 Key U S Style Keyboard 105 Key European Style Keyboard...