background image

Symbologies

nlscan.com

Page  79

Code Programming ON

Code Programming OFF

Tools

"Code Programming ON"

1. 

"Select Min Message Length"

2. 

Digit code "8", see Digit Code 

3. 

"Save Programming", see Digit Code 

4. 

"Select Max Message Length"

5. 

Digit code "1"

6. 

Digit code "2"

7. 

"Save Programming"

8. 

"Code Programming OFF"

9. 

QR Code

Select Message Length

It is used to program the valid reading length (bytes) of QR Code. The engine will produce an 

error beep, if the data length captured does not match the valid reading length.

QR Code Message Length is defined by "Min. Message Length" and "Max. Message Length".

Min Message Length (default: 1)

Pro CMD

0502030

Max Message Length

default:7098 

Pro CMD

0502040

2D bar code Message Length should not exceed 65535 bytes. 
Max Message Length should not be shorter than Min Message Length. 
To read a fixed length QR Code, Please program Max & Min Message Length to the same value 

Program QR Code, Min Message Length 8 bytes, Max Message Length 12 bytes.

Summary of Contents for NLS-FM200

Page 1: ...NLS FM200 Mobile 2D Barcode Scanner User Guide Latest 20081015...

Page 2: ...RESTART 9 Power On 9 Power Off 9 IDLE Mode 9 RESTART 9 Programming Outline 10 Introduction 10 Code Programming 10 Command Programming 11 Reading 12 Illumination 13 Aiming 14 Reading Mode 15 Mode Sele...

Page 3: ...Check 38 Data Bits Transmitted 39 Stop Bits 40 Introduction 41 Symbologies Selections 41 Symbologies 41 General Options 42 Prohibit Reading All 42 Allow Reading All 42 Allow Reading All 1D 42 Prohibit...

Page 4: ...of 5 56 Select Message Length 57 Check Byte 58 Fixed Length Selection 59 ITF 14 60 ITF 6 61 China Post 25 62 Load Factory Default 62 Read Abort China Post 25 62 Select Message Length 63 Check Byte 64...

Page 5: ...Select Message Length 85 Data Matrix Twin Code 86 Chinese Sensible Code 87 Load Factory Default 87 Read Abort Chinese Sensible Code 87 Select Message Length 88 OCR Selections 89 Inrtuducation 89 Prefi...

Page 6: ...ain 1D barcode Intersection Setting 101 Message Intersect 102 2D Program Intersect Option 102 How to clear a certain 2D barcode Intersection Setting 102 Symbologies ID Number 103 Message Pack 104 Intr...

Page 7: ...introduces a Newland Auto ID Image product NLS FM200 ab FM200 Graphic Emphasis TOOL facilitate use of the manual ATTENTION be aware read through E g help understand a certain operation TIPS help under...

Page 8: ...fast and accurate performance and thus provide the best value It works at hand held and hands free modes in a stand The ergonomic design allows comfort and easy use Chapter One presents a holistic pic...

Page 9: ...e 3 Unpacking Unpack FM200 and accessories Check with the packing list to make sure that there is none damaged or missing If any please keep the original package and contact your supplier for services...

Page 10: ...Page 4 Getting Start RS 232 Port Cable Slot PIN Functions I O 1 GND 2 VIN 3 VIN 4 RS232 TXD OUT 5 RS232 RXD IN 6 RS232 CTS IN 7 RS232 RTS OUT 8 GND 9 USBC_D 10 USBC_D PIN 1 PIN 10 Familiar with FM200...

Page 11: ...ISBN ISSN Code 93 etc Precision 3mil Light Source LED 622 nm 628 nm Light Intensity 290 LUX 130 mm Depth of Scan Field 0 mm 450 mm Print Contrast Signal 25 Roll 360 Pitch 45 Yaw 45 Illumination 0 100...

Page 12: ...imager Must connect with a Host to perform A Host can be PC POS Or any intelligent terminal with supported communication ports US 1 B USB port on host RS23 2 2 RS232 port on host Please check availabl...

Page 13: ...Cable Insert USB Cable RJ45 male head into cable slot HR200 1 Insert USB Cable USB male head into USB slot Host female slot 2 Switch ON and perform 3 You may need to install driver into the host to pe...

Page 14: ...RS232 Cable Connect FM200 Host Insert RS232 cable RJ 45 male head into cable slot HR200 1 Insert RS232 cable RS232 male head into RS232 slot Host female slot 2 Connect RS232 cable and the mains with...

Page 15: ...N Power Off 4 ways to Power OFF Remove Cable Off HR200 Remove Power Adapter Off RS232 Cable Remove USB Cable Off the Host Remove PS 2 cable off the Host IDLE Mode When Imager is NOT reading it is in I...

Page 16: ...ogramming work on choose set options base from dialog windows Note Programming results restore in non volatile memories and will not lose when Power OFF Code Programming Please read Code Programming O...

Page 17: ...nls0100060 set RS232 transmit Baud Rate to 38400bps nls Pro CMD Decimal Parameter 2 It is used to define parameter such as Min Message Length E g nls0312040 10 select Sensor Mode Sensitivity to be 10...

Page 18: ...The Sensor Mode or Continuous Mode should be selected See Reading Mode for details Because FM200 does not have a manual trigger and it is a fix mount reader Mobile phone screen should be facing the sc...

Page 19: ...re are 4 options Illumination Wink LED keep flashing when reading Illumination Keep ON LED keep on when Power ON Illumination Read ON LED keep on when reading Illumination OFF LED is off all the time...

Page 20: ...Aim OFF Pro CMD 0201020 Aiming LED focusing with a cross is used to allocate the Optimum Reading Stance There are 4 options Aim Wink LED keep flashing when reading Aim Keep ON LED keep on when Power O...

Page 21: ...itch to idle Both luminance changing and the Trigger can initiate reading when idle Continuous Mode one hit the Trigger to start continuous reading and on hit to terminate reading Hand held Mode Pro C...

Page 22: ...ensitivity value is 0 20 including The lower the sensitivity value chosen the higher sensitivity will be The lower the sensitivity value chosen the smaller illumination change will initiate reading Re...

Page 23: ...Near mm Far mm Code 39 5 0 15 Code 39 10 0 25 PDF417 5 0 20 PDF417 10 0 30 QR Code 10 0 25 QR Code 15 0 36 Data Matrix 10 0 25 Data Matrix 15 0 40 Reading Stance is defined as the distance between the...

Page 24: ...lti reading Prohibition By all means constrain reading on the same barcode in the timeout Multi reading Semi prohibition Given a slight change on operation circumstances the same barcode can be read m...

Page 25: ...mming and wish to decline their affection while programming 2 commencing Resume default if unusual unknown unexpected options are selected 3 Load All Factory Default Pro CMD 0001000 User Default All u...

Page 26: ...nary barcode 2 beeps successful read of an programming barcode 3 short low 2 high failure read 1 long low Unknown Character Virtual Keypad USB connection Program Beeper Read Beep ON to enable all beep...

Page 27: ...te data bit and stop bit in the 2 order PS 2 no append narration 3 1D Indicate that reading 1D is allowed Symbologies are divided by comma Appended information 1 affiliate features 2 Min Message Lengt...

Page 28: ...the only work needs to do Improper maintenance will avoid limited warranty Avoid rough object damage or scratch the window Use brush to remove the stain Use soft cloth cloth of glasses to clean Prohib...

Page 29: ...n and user preference programming QuickSet can perform with DataPipe USB DataPipe can be emulated to RS232 input into the Host The virtual RS232 connection use DB9 DIN and perform exactly the same as...

Page 30: ...s simulating the Imager transmission to be a USB keyboard input The Host receives keystrokes of the virtual keyboard It works in Plug and Play base There is no driver required Select USB HID KBW Pro C...

Page 31: ...ry codes to the table USB Country Keyboard Types Follow the steps bellow to program 1 Code Programming ON 2 Select Country Code 3 Read digit codes according to country code 4 save programming 5 Code P...

Page 32: ...14 Belgium 1 Norway 15 Brazil 2 Poland 16 Canada French 3 Portugal 17 Czechoslovakia 4 Romania 18 Denmark 5 Russia 19 Finland Sweden 6 Slovakia 21 France 7 Spain 22 Germany Austria 8 Sweden 23 Greece...

Page 33: ...be able to allocate and send a keystroke thus lead to an error beep No Beep Unkown Character Pro CMD 1103030 Beep Unkown Character Pro CMD 1103031 Suppose select country keyboard types France number 7...

Page 34: ...Make ALT Break No Emulate ALT keypad Pro CMD 1103060 Emulate ALT keypad Pro CMD 1103061 Regardless country keyboard selections full ASCII characters 0x00 0xff can be sent Sending speed is slow Suppose...

Page 35: ...ak No Function Key Mapping Pro CMD 1103130 Function Key Mapping Pro CMD 1103140 USB HID KBW set to be factory default Enable Emulate CTRL keypad Read barcode A tab F 0x65 0x09 0x70 The sequence is 1 K...

Page 36: ...Function Key Mapping Table ASCII HEX Function key ASCII HEX Function Key 00 2 10 P 01 A 11 Q 02 B 12 R 03 C 13 S 04 D 14 T 05 E 15 U 06 F 16 V 07 G 17 W 08 H 18 X 09 I 19 Y 0A J 1A Z 0B K 1B 0C L 1C...

Page 37: ...of data No Delay Pro CMD 1103050 Medium Delay 20ms Pro CMD 1103051 Long Delay 40ms Pro CMD 1103052 CAPS Lock Override The case of the data is inverted regardless of the state of the Caps Lock key on t...

Page 38: ...ols USB HID KBW Convert Case The Imager converts all barcode messages to the selected case No Case Conversion Pro CMD 1103040 Convert All to Upper Case Pro CMD 1103041 Convert All to Lower Case Pro CM...

Page 39: ...this function Enable Emulate ALT keypad will automatically disable this function Enable Visual Number Keyboard and read the A4 5 barcode If Num Lock on the host is ON the data received will be A4 5 If...

Page 40: ...his protocol is defined by Newland Auto ID A driver has to be installed before using this protocol to communicate with reader The advantage of using this protocol is the speedy data transmission Meanw...

Page 41: ...the USB port is connected to host RS232 port in order to receive data from scanner the model of imitating USB to RS232 has to be chosen Hence the engine and the host must communicate at the same param...

Page 42: ...nlscan com Page 36 RS232 Interface Inteuduction Under RS232 connection the engine and the Host should use the same communication parameters baud rate parity check data bits select and stop bits select...

Page 43: ...er second 8 bits per bytes The engine and the Host must communicate at the same baud rate The reader supports baud rate as following 9600 Pro CMD 0100030 2400 Pro CMD 0100010 14400 Pro CMD 0100040 384...

Page 44: ...S232 Interface Code Programming ON Code Programming OFF Tools Parity check options should be the same on the engine and the Host NO Check Pro CMD 0101000 Even Check Pro CMD 0101010 Odd Check Pro CMD 0...

Page 45: ...ogramming OFF Tools Data Bits Transmitted Select data bits transmitted to be 5 6 7 and 8 Ensure the selections on the engine and the Host are the same 8 Data Bits Pro CMD 0103030 7 Data Bits Pro CMD 0...

Page 46: ...Interface Code Programming ON Code Programming OFF Tools Stop bit follows every byte to indicate the end of transmission and the start of the next transmission 1 Stop Bit Pro CMD 0102000 2 Stop Bits P...

Page 47: ...t 1D Barcode C o d e 1 2 8 Allow Reading U C C E A N 8 Allow Reading E A N 1 3 Allow Reading U P C E Allow Reading U P C A Allow Reading I n t e r l e a v e d 2 o f 5 Allow Reading C h i n a P o s t 2...

Page 48: ...g All Pro CMD 0001010 Allow Reading All Allow Reading All enable to read all symbologies and programming codes Allow Reading All Pro CMD 0001020 Allow Reading All 1D Allow Reading All 1D Pro CMD 00010...

Page 49: ...Abort Code 128 Pro CMD 0400010 Abort Code 128 prohibits the engine to read Code 128 Please read programming code Read Code 128 when the engine can not read Code 128 Read Abort Code 128 Check Pro CMD 0...

Page 50: ...ode Message Length should not exceed 127 bytes Max Message Length should not be shorter than Min Message Length To read a fixed length Code 128 Please program Max Min Message Length to the same value...

Page 51: ...Pro CMD 0401010 Abort UCC EAN 8 prohibits the engine to read UCC EAN 8 Please read programming code Read UCC EAN 8 when the engine can not read UCC EAN 8 Check Byte UCC EAN 8 is fixed 8 characters bar...

Page 52: ...Pro CMD 0401050 Read 2 Digits Addenda Pro CMD 0401060 Abort 5 Digits Addenda Pro CMD 0401070 Read 5 Digits Addenda Pro CMD 0401080 2 Digits Addenda Code Addenda code is the one follows on the right si...

Page 53: ...de Programming ON Code Programming OFF Tools UCC EAN 8 EAN 8 expand to EAN 13 Expand EAN 8 to EAN 13 by adding 5 bytes of 0 to the left and then transmit Not Expand to EAN 13 Pro CMD 0401090 Expand to...

Page 54: ...D 0402000 Read EAN 13 Pro CMD 0402020 Abort EAN 13 Pro CMD 0402010 Read Abort EAN 13 Abort EAN 13 prohibits the engine to read EAN 13 Please read programming code Read EAN 13 when the engine can not r...

Page 55: ...a Pro CMD 0402050 Read 2 Digits Addenda Pro CMD 0402060 Abort 5 Digits Addenda Pro CMD 0402070 Read 5 Digits Addenda Pro CMD 0402080 2 Digits Addenda Code Addenda code is the one follows on the right...

Page 56: ...ult Pro CMD 0403000 Read Abort UPC E Read UPC E Pro CMD 0403020 Abort UPC E Pro CMD 0403010 Abort UPC E prohibits the engine to read UPC E Please read programming code Read UPC E when the engine can n...

Page 57: ...with a 2 digits addenda code The left one with blue circle is an ordinary code The right one with red circle is the 2 digits addenda code Read 2 Digits Addenda read an ordinary code and 2 digits adde...

Page 58: ...t character of UPC E is a system digit The value of system digit is fixed as 0 Don t Transmit First 0 Pro CMD 0403090 Transmit First 0 Pro CMD 0403100 Extend To UPC A Selections To enable or disable U...

Page 59: ...ro CMD 0404000 Read Abort UPC A Read UPC A Pro CMD 0404020 Abort UPC A Pro CMD 0404010 Abort UPC A prohibits the engine to read UPC A Please read programming code Read UPC A when the engine can not re...

Page 60: ...a Pro CMD 0404050 Read 2 Digits Addenda Pro CMD 0404060 Abort 5 Digits Addenda Pro CMD 0404070 Read 5 Digits Addenda Pro CMD 0404080 2 Digits Addenda Code Addenda code is the one follows on the right...

Page 61: ...rogramming OFF Tools UPC A Transmit Selections UPC A the first byte very left one is default 0 No Transmit 0 Pro CMD 0404090 Transmit 0 Pro CMD 0404100 UPC A has the default 0 but it is not printed ou...

Page 62: ...nterleaved 2 of 5 Factory Default Pro CMD 0405000 Read Abort Interleaved 2 of 5 Read Interleaved 2 of 5 Pro CMD 0405020 Abort Interleaved 2 of 5 Pro CMD 0405010 Abort Interleaved 2 of 5 prohibits the...

Page 63: ...gth should not exceed 127 bytes Max Message Length should not be shorter than Min Message Length To read a fixed length Interleaved 2 of 5 Please program Max Min Message Length to the same value Min M...

Page 64: ...de message and Check Byte Check Transmit No Check enables to read and check If verification is successful transmit barcode message if not engine produce an error beep Check Transmit All enables to rea...

Page 65: ...able Fixed Length Selection Pro CMD 0405150 Undo Code Length Selection Pro CMD 0405170 The engine only read Interleaved 2 of 5 which are 12 and 24 bytes 1 Code Programming ON then Select Code Length 2...

Page 66: ...4 Selection Prevail the selection of ITF 14 if any affects and prevail the selection of the Interleaved 2 of 5 when they have the same feature as ITF 14 Disable ITF 14 User Selection Pro CMD 0405080 I...

Page 67: ...ITF 6 ITF 6 Selection Prevail the selection of ITF 6 if any affects and prevails the selection of the Interleaved 2 of 5 when they have the same feature as ITF 6 Disable ITF 6 User Selection Pro CMD...

Page 68: ...ctory default Load China Post25 Factory Default Pro CMD 0406000 Read Abort China Post 25 Abort China Post 25 Pro CMD 0406010 Read China Post 25 Pro CMD 0406020 Abort China Post 25 prohibits the engine...

Page 69: ...f China Post 25 The engine will produce an error beep if the data length captured does not match the valid reading length China Post 25 Message Length is defined by Min Message Length and Max Message...

Page 70: ...is successful transmit barcode message if not Imager produce an error beep Check Transmit All enables to read and check If verification is successful transmit all message if not Imager produce an erro...

Page 71: ...Read Abort Code 39 Read Code 39 Pro CMD 0408020 Abort Code 39 Pro CMD 0408010 Abort Code 39 prohibits the engine to read Code 39 Please read programming code Read Code 39 when the engine can not read...

Page 72: ...Code 39 The engine will produce an error beep if the data length captured does not match the valid reading length Code 39 Message Length is defined by Min Message Length and Max Message Length Min Mes...

Page 73: ...is successful transmit barcode message if not Imager produce an error beep Check Transmit All enables to read and check If verification is successful transmit all messages if not Imager produces an e...

Page 74: ...Tools Code 39 Decode ASCII Code 39 can include full ASCII characters For factory default the engine enabled to decode partial of them Read Enable Full ASCII decode to select full ASCII functions Parti...

Page 75: ...ro CMD 0409020 Abort Codabar Pro CMD 0409010 Abort Codabar prohibits the engine to read Codabar Please read programming code Read Codabar when the engine can not read Codabar Transmit Start Stop Chara...

Page 76: ...Codabar The engine will produce an error beep if the data length captured does not match the valid reading length Codabar Message Length is defined by Min Message Length and Max Message Length Min Mes...

Page 77: ...ransmit NO Check Pro CMD 0409060 Check Transmit All Pro CMD 0409070 Check Byte Codabar may include Check Byte not compulsory following its barcode message Check Byte is used to verify the barcode mess...

Page 78: ...Default Read to load Code 93 factory default Load Code 93 Factory Default Pro CMD 0410000 Read Abort Code 93 Abort Code 93 Pro CMD 0410010 Read Code 93 Pro CMD 0410020 Abort Code 93 prohibits the eng...

Page 79: ...ytes of Code 93 The engine will produce an error beep if the data length captured does not match the valid reading length Code 93 Message Length is defined by Min Message Length and Max Message Length...

Page 80: ...CMD 0410060 Check Transmit All Pro CMD 0410070 Check Byte Codd 93 may include Check Byte not compulsory following its barcode message Check Byte is used to verify the barcode message NO Check Transmi...

Page 81: ...load UCC EAN 128 factory default Load UCC EAN 128 Factory Default Pro CMD 0412000 Read Abort UCC EAN 128 Read UCC EAN 128 Pro CMD 0412020 Abort UCC EAN 128 Pro CMD 0412010 Abort UCC EAN 128 prohibits...

Page 82: ...fault Read to load PDF417 factory default Load PDF417 Factory Default Pro CMD 0501000 Read Abort PDF417 Read PDF417 Pro CMD 0501020 Abort PDF417 Pro CMD 0501010 Abort PDF417 prohibits the engine to re...

Page 83: ...t 2710 Pro CMD 0501040 Select Message Length It is used to program the valid reading length bytes of PDF417 The engine will produce an error beep if the data length captured does not match the valid r...

Page 84: ...lt Read to load QR Code factory default Load QR Code Factory Default Pro CMD 0502000 Read Abort QR Code QR Code Pro CMD 0502020 Abort QR Code Pro CMD 0502010 Abort QR Code prohibits the engine to read...

Page 85: ...es of QR Code The engine will produce an error beep if the data length captured does not match the valid reading length QR Code Message Length is defined by Min Message Length and Max Message Length M...

Page 86: ...R Code and abort twin code Twin QR Only Select to read only twin code and abort single QR Code code The working sequence is Detect Twin Code Yes Decode Twin Code Yes Transmit Upper Left QR Yes Transmi...

Page 87: ...oad Aztec Code factory default Load Aztec Code Factory Default Pro CMD 0503000 Read Abort Aztec Code Read Aztec Code Pro CMD 0503020 Abort Aztec Code Pro CMD 0503010 Abort Aztec Code prohibits the eng...

Page 88: ...th bytes of Aztec The engine will produce an error beep if the data length captured does not match the valid reading length Aztec Message Length is defined by Min Message Length and Max Message Length...

Page 89: ...ture Read the single Aztec Code only Model 2 Enable Multi Barcodes feature with the number of bar codes specified Model 3 Enable Multi Barcodes feature the system processes multi Barcodes simultaneous...

Page 90: ...Matrix factory default Load Data Matrix Factory Default Pro CMD 0504000 Data Matrix Pro CMD 0504020 Abort Data Matrix Pro CMD 0504010 Read Abort Data Matrix Abort Data Matrix prohibits the engine to...

Page 91: ...The engine will produce an error beep if the data length captured does not match the valid reading length Data Matrix Message Length is defined by Min Message Length and Max Message Length Min Message...

Page 92: ...x and abort twin code Twin Data Matrix Only select to read only twin code and abort single Data Matrix code The working sequence is Detect Twin Code Yes Decode Twin Code Yes Transmit Upper Left code Y...

Page 93: ...ble Code Factory Default Pro CMD 0508000 Read Abort Chinese Sensible Code Read Chinese Sensible Code Pro CMD 0508020 Abort Chinese Sensible Code Pro CMD 0508010 Abort Chinese Sensible Code prohibits t...

Page 94: ...Code The engine will produce an error beep if the data length captured does not match the valid reading length Chinese Sensible Code Message Length is defined by Min Message Length and Max Message Le...

Page 95: ...tion is the technology that capture image of printed information and recognize the image to editable characters The engine satisfy OCR B standard and support specific typeface Disable OCR Pro CMD 0600...

Page 96: ...ample the barcode format the date or a new line character can be useful Mostly these informations are not included in a barcode and thus to keep it short and flexible possible Prefix Suffix appended t...

Page 97: ...eID prefix AIM prefix User prefix User suffix and Stop suffix to the barcode message Prohibit All Prefix Suffix Pro CMD 0311000 Allow All Prefix Suffix Pro CMD 0311010 CodeID AIM User Prefix Pro CMD 0...

Page 98: ...Pro CMD 0305010 Program User Prefix Read Program User Prefix Then program user prefix in order by reading their hex respectively Note The maximum length for user prefix is 10 bytes Program User Prefi...

Page 99: ...r Code128 1 Characters Mode Append AIM prefix 0 2 Full Characters Mode Append AIM prefix 0 3 No AIM Prefix Pro CMD 0308000 2 Characters Mode Pro CMD 0308020 1 Character Mode Pro CMD 0308010 Full Chara...

Page 100: ...CodeID Prefix Pro CMD 0307000 Allow CodeID Prefix Pro CMD 0307010 Symbologies CodeID Default Hex Code128 UCC EAN 128 j 6A UPC E UPC A c 63 EAN 8 EAN 13 d 64 Interleaved 2 OF 5 China Post25 e 65 Code39...

Page 101: ...g OFF Modify PDF417 CodeID to be p 1 Read Code Programming ON 2 Read Modify PDF417 3 Read digit code 7 0 4 Read Save Programming 5 Read Code Programming OFF Load CodeID factory default including PDF41...

Page 102: ...ved 2 of 5 Pro CMD 0004080 Modify Codabar Pro CMD 0004150 Modify UPC E Pro CMD 0004060 Modify China Post25 Pro CMD 0004110 Modify Code 93 Pro CMD 0004170 Modify EAN 8 Pro CMD 0004040 Modify UPC A Pro...

Page 103: ...fix Pro CMD 0306010 Program User Suffix Read Program User Suffix Then program user prefix in order by reading their hex respectively Note The maximum length for user suffix is 10 bytes Program User Su...

Page 104: ...9000 Allow Stop Suffix Pro CMD 0309010 Program Stop Suffix Read Program Stop Suffix Then program Stop Suffix in order by reading their hex respectively Note The maximum length for Stop Suffix is 2 byt...

Page 105: ...as merchandise ID manufacturer and so on Intersection can select section s required to transmit and thus to skip other unnecessary sections in the result shown Normally the processing sequence is read...

Page 106: ...Code 128 Code 39 QR Code Program UPC A intersection option and save The 3 options restored in order should be Code 39 QR Code UPC A Intersection Rule No 3 For one barcode format if there are more than...

Page 107: ...ing the 4th digit the 1st digit How to clear a certain 1D barcode Intersection Setting E g If you want to cancel the EAN 13 Intersection Settings take the processing as below Read Enable Code Programm...

Page 108: ...0 3 3 0 0 0 0 0 0 0 0 1 0 0 0 0 2 0 0 0 0 0 0 1 0 1 3 0 0 1 0 4 0 symbology ID ascending the 1st digit the 20thdigit descending the 113th digit the 140th digit How to clear a certain 2D barcode Inter...

Page 109: ...Number Code 128 002 UCC EAN128 003 EAN 8 004 EAN 13 005 UPC E 006 UPC A 007 Interleaved 2 OF 5 008 China Post25 011 Code 39 013 Codabar 015 Code 93 017 PDF417 032 QR Code 033 Aztec 034 DataMatrix 035...

Page 110: ...efault Disable Pack if pack is not required Disable Pack Pro CMD 0314000 Normal Pack Normal pack format STX ATTR LEN AL_TYPE DATA LRC STX 0x02 ATTR 0x00 LEN Barcode message length is expressed by 2 by...

Page 111: ...rogramming OFF Tools ESC_Bank Pack ESC_BANK pack format STX DATA ETX BCC STX 0x02 DATA Barcode message ETX 0x03 BCC Parity byte The algorithm 1 computation sequence is BCC STX DATA ETX 2 computation m...

Page 112: ...ode message length is expressed by 4 bytes Every byte for an ASCII and thus it ranges 0 9999 For example LEN 0x30303137 refer to the ASCII chart for decimal value 0x30303137 0017 0x30 0 0x31 1 0x37 7...

Page 113: ...sub command and its terminator semicolon 3 Save Programming 0000160 to terminate 4 Use Barcode Generator software to make the 2D batch barcode For example to generate a batch barcode for Illumination...

Page 114: ...0 Pro CMD 0000000 3 Pro CMD 0000030 6 Pro CMD 0000060 9 Pro CMD 0000090 C Pro CMD 0000120 F Pro CMD 0000150 1 Pro CMD 0000010 4 Pro CMD 0000040 7 Pro CMD 0000070 A Pro CMD 0000100 D Pro CMD 0000130 2...

Page 115: ...a program code is received then 1 2 3 in order is received if then read Abort One Data of Current Setting the 3 will be deleted if read Abort One String of Current Setting the 123 will be deleted if r...