nlscan.com
Page 59
Symbologies
Code Programming ON
Code Programming OFF
Tools
Interleaved 2 of 5
Fixed Length Selection
Program the engine to read fixed length or fixed length area Interleaved 2 of 5. Command
programming use 3 decimal digits to define length value. The fixed length value MUST be 2 to 64
even value (32 even values).
When enabled, Interleaved 2 of 5 Selection prevail
“
Message Length Selection
”
** Disable Fixed Length Selection
【
Pro CMD
:
0405140
】
Select Code Length
【
Pro CMD
:
0405160
】
Enable Fixed Length Selection
【
Pro CMD
:
0405150
】
Undo Code Length Selection
【
Pro CMD
:
0405170
】
The engine only read Interleaved 2 of 5 which are 12 and 24 bytes.
1.
“
Code Programming ON
”
, then
“
Select Code Length
”
2.
Digit Code
“
0
”
,
“
1
”
,
“
2
”
3.
“
Save Programming
”
4.
Digit Code
“
0
”
,
“
2
”
,
“
4
”
5.
“
Save Programming
”
, then
“
Code Programming OFF
”
The engine only read Interleaved 2 of 5 between 12 bytes and 24 bytes.
1.
“
Code Programming ON
”
, then
“
Select Code Length
”
2.
Digit Code
“
0
”
,
“
1
”
,
“
2
”
,
then read
“
0
”
,
“
2
”
,
“
4
”
3.
“
Save Programming
”
, then
“
Code Programming OFF
”
Undo fixed length selections between 2 bytes and 64 bytes.
1.
“
Code Programming ON
”
, then
“
Undo Code Length Selection
”
2.
Digit Code
“
0
”
,
“
0
”
,
“
2
”
, then read
“
0
”
,
“
6
”
,
“
4
”
3.
“
Save Programming
”
, then
“
Code Programming OFF
”