6. STORAGE AND MAINTENANCE INSTRUCTIONS. 

 

Precautions: 

LRB is a sophisticated precision optical instrument 

equipped with electronics. Therefore, it should be handled with 
due care. 

 

Keep your device away from direct sunlight, impacts, dust, 
moisture, and sudden changes of temperatures. 

 

Do not use the device at temperatures higher than 50

o

(122

o

F). 

 

 

Do not touch the optical surfaces with fingers.  Doing so 
may damage the anti-reflection coating. 

 

 

Avoid shocks and sharp jolts. 

 

Cleaning of optical surfaces is allowed with professional 
camera lens cleaning supplies only. 

 

 

To clean the exterior of the device, use a soft clean cloth.   

 

Keep away from heating appliances and central heating. 

 

Remove the battery when storing the device for long time. 

 

All repair works must be performed by an authorized service 
only. 

 

 
 

14 

4. 

TECHNICAL CHARACTERISTICS

 

1. Optics 

 

Magnification, x 
Objective lens, mm 
Exit pupil diameter, mm 
Field of view 
Type of coating 

50 

5

°

 

Fully multi-coated optics 

2. Range 

Finder 

 

Type 
Measuring range, m 
Accuracy 
'Last Target' measurement 
Meters/Yards display 
Last 10 readings recall 
Reticle shape (+ or 

G

Target quality indicator 

Class 1, eye safe, 905nm 

20 – 1,512 

±

 1m 

±

 0.1%  

Yes  
Yes 
Yes  
Yes  

Optional  

3. Speed 

Detection 

Model LRB 7x50SPD only 
 - Measured speed range, KMH 
 - Accuracy, KMH 

Yes 

5 – 400 

±

 1 

4. Misc. 

 

Battery 
'Low Battery' indicator 
Tripod thread 
Operational temperature range 
Storage temperature range 
Weight without battery, g 
Dimensions, mm 

9 V 

Yes 

¼” x 20 

-25 / +50

o

C (-13 / +122

o

F) 

-45 / +85

o

C (-49 / +185

o

F) 

1300 

210x150x80 

Summary of Contents for LRB 7x50

Page 1: ...NEWCON OPTIK 2008 Printed in Canada Operation Manual LRB 7x50 LRB 7x50 SPD LASER RANGEFINDER BINOCULAR In USA 2331 Superior Ave Cleveland OH 44114 In Canada 105 Sparks Ave Toronto ON M2H 2S5...

Page 2: ...or being transported NEVER transport the unit without the case NEVER disassemble the unit This device contains high voltage components which may be hazardous for you NEVER reverse polarity of the batt...

Page 3: ...r Rangefinder Binocular Latest digital circuitry allows targeting through most types of glass Last Target measurement Meters Yards display Last 10 readings recall Selectable reticle shape or G Target...

Page 4: ...t data for the calculations determining the distance to the target 4 9 CUSTOMER SUPPORT Should you experience any difficulties with your Newcon OPTIK product consult the enclosed manual If the problem...

Page 5: ...N is not responsible for warranty service should the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect damage caused by disa...

Page 6: ...e at the new target press the Action button The new reading will appear There are black dots in the image A LCD Liquid Crystal Display is installed in the optical channel of the device Due to manufact...

Page 7: ...pliances and central heating Remove the battery when storing the device for long time All repair works must be performed by an authorized service only 14 4 TECHNICAL CHARACTERISTICS 1 Optics Magnifica...

Page 8: ...degrade Please note this indicator is optional and may be not activated in your device The display presents LOW BATTERY pictogram when voltage of the primary 9 volt battery drops below 7 2 volt At thi...

Page 9: ...he measured distance TARGET REFLECTION HIGH when the number of steady received reflected signals is qualified to be enough to make reliable conclusion about the measured distance 12 5 1 Preparing the...

Page 10: ...state By pressing the Mode button you can sequentially scan the Modes 10 The Mode under selection is being indicated on the Display by flashing of the selectable feature The flashing feature can be s...

Reviews: