Optional scanning mode:
If the Action button (6) is held
(pressed) for more than 3 seconds, the System automatically
enters SCANNING mode. Being in this mode, the System
repetitively performs distance measuring and displaying.
The time interval between measurements is approximately 1
second.
Please note:
this feature is optional and not necessarily
present in your device.
The maximum measuring range for most objects will be 1512
meters. The maximum measured distance will vary greatly
depending on the reflectivity of the target, weather conditions
and more.
Target reflectivity depends on its color, surface finish, shape etc.
Bright colors are more reflective than darks. A polished surface
is more reflective than a rough one. Larger targets are easier for
distance measuring. Measuring a target faced at 90
o
(perpendicular to the laser beams path) provides optimal results.
Bad weather conditions (rain, fog, snow, mist) will reduce the
maximum measured range.
Bright sunny days will reduce performance as well
While the unit will work through many glass types, measuring
through glass will affect the results.
b. Mode selection state
Pressing MODE button (5) when the System is in READY mode
brings the System to the Mode selecting state. By pressing the
Mode button, you can sequentially scan the Modes.
10
The Mode under selection is being indicated on the Display by
flashing of the selectable feature. The "flashing" feature can be
selected by pressing the Action button (6).
The System operates in the setting Modes that are displayed as
follows (refer to fig.3):
Y/M
– units of measurement: yards or meters (3).
KMH/MPH
– units of speed measurement: km/hour or
miles/hour (3).
Please note:
the speed-measuring units exist in
LRB 7x50 SPD only.
Shape
of the reticle: cross shape or rectangular shape (2).
Please
note:
this feature is optional and not necessarily present in your
device.
rEC1
- recall function. Upon pressing the Action button (6) (fig.
1) the Display will sequentially show results of last 10
measurements, starting from the latest one. The number
appearing after word "
rEC
" shows the number of the
measurement counted back in the sequence. When the System is
in inactive state the 10 previous measurements are stored within
the System and may be recalled any time;
CL
- clear data function: upon pressing the Action button (6)
(fig. 1) the entire data on all previous measurements will be
erased.
Please note:
After changing a battery the recall stack
should be cleared by exercising the
CL
mode.
Self-test (optional)
– checks the display by turning on all
display segments during 5 seconds.
Please note:
this feature is
optional and not necessarily present in your device.
11