MACHINE PROGRAMMING CONT’D

 

 

 
 

Flowmeter Adjustment

This entry displays the value used to represent the amount 

of liquid for one tick of the flow meter count.  Each tick adjusts the value approximately 2/10

th 

of 

an ounce.  While in this entry, pressing the A key will decrement and the B key will increment 
this value. This can be used to fine-tune the amount of liquid that is dispensed. The default

 

value is 0.

 

 

Recipe Settings

: This entry takes the user into a sub menu to program the parameters 

unique to each key. When this entry is accessed the display will change to SELECT BUTTON 
indicating that the user should press the brew key (button B, C or D, E or F (see Fig 1)) to be 
programmed. When a brew key is selected the display will show the first entry in the Button Set 
up sub menu, PRE-INFUSION. While SELECT BUTTON is displayed the user may exit back to the 
Main menu by Pressing the Hot Water key (G) (see Fig 1).

 

 

With these four entries in the BUTTON SET UP sub menu:

 

 

SET PRE-INFUSION TIME

: This entry sets the time of the pre-infusion pulse of water in 

tenths of a second. Range is 1 to 30, the default is 15 tenths of a seconds.

 

 

SET BREW VOLUME

: This entry sets the volume in tenths of an ounce for this key to 

dispense. The Range is from 20 to 160 tenths of an ounce with the default set to 70 tenths of 
an ounce

 

 

SET BREW TIME

: This entry sets the brew time in seconds for a 7-ounce cup of coffee with 

on/off pulses. The range is from ~30 to 99 seconds with the default being 35 seconds.

 

 

EXIT

: Exit to Main Programming Menu.

 

 

Select Water Filter

: This entry allows the user to select the filter size for the filter used 

on the inlet for the water. Choices include OFF, 500 GAL UP TO 3000 GAL. These set the counter 
for the filter warning. Whenever water is dispensed the counter is incremented to account for

 

the water dispensed. When the counter is above 90% of the capacity of the chosen filter a 
w

arning message, “CHECK FILTRATION ”, is displayed in place of the “READY” message. To 

reset the counter the user must enter the programming menu and enter the RESET FILTER entry 
described below. The following entries only show  when a filter is selected. If the filter selection 
is OFF then following entries are not available. Pressing the Hot Water key (G) (see Fig 1) to 
leave the entry and return to the Main Programming menu.

 

 

GAL. REMAINING

: This entry scrolls the number of Gallons left before the filter should be 

replaced. Pressing the Hot Water key (G) (see Fig 1) to leave the entry and return to the Main 
Programming menu.

 

 

RESET FILTER

: When in this entry the message 

“PRESS OPEN TO RESET FILTER’. Press the 

Open Door key will reset the Filter Use counter to the value chosen in the SELECT WATER 
FILTER entry above. Pressing the Hot Water key (G) (see Fig 1) to leave the entry and return to 
the Main Programming menu.

 

 

 
 

EXIT MENU: 

– Exit to Ready to Brew Mode and save parameters.

 

Summary of Contents for FKP-3

Page 1: ...P 3 NEWCO ENTERPRISES INC 3650 NEW TOWN BLVD SAINT CHARLES MO 63301 1 800 325 7867 FAX 1 636 925 0029 Features Specifications AUTOMATIC POD REMOVAL FLOWMETER 20 OZ TRAVEL MUG LARGE POD WASTE TRAY THRU...

Page 2: ...2 LEFT BLANK INTENTIONALLY...

Page 3: ...SET UP 6 MACHINE OPERATION 7 MACHINE PROGRAMMING 7 DRAINING THE HOT WATER TANK 11 SERVICING THE MACHINE 11 REMOVING THE BREW MECHANISM 11 SIDE PANEL REMOVAL 12 TANK REMOVAL ACCESS AREAS 13 POD BREWING...

Page 4: ...1700W 120V CANADA 1400W 120V INTERNATIONAL 1700W 220V TANK CAPACITY 1 US GALLON DRIP TRAY CAPACITY 8 OUNCES POD WASTE TRAY CAPACITY 40 PODS USE WASTE TRAY PN 780306 FOR THRU COUNTER USE UP TO 20 OZ C...

Page 5: ...ranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location a...

Page 6: ...t run use 1 4 tubing and connect to 1 2 or larger water line The inlet water fitting on the back of the brewer is a 1 4 flare fitting It may be necessary to remove the plumbing cover box on the rear o...

Page 7: ...BE SHUT OFF AIR PUMP POD DRYING TIME PUMP STRENGTH CAN BE ADJUSTED POD COUNT TO EMPTY POD WASTE BIN AJDUSTABLE OR CAN BE TURNED OFF IF USING THROUGH THE COUNTER WASTE BIN COFFEE OR TEA PRE INFUSTION B...

Page 8: ...TS ARE NECESSARY IF THE FACTORY DEFAULTS ARE USED G A B C D E F Fig 1 Fresh Cup Keys The Fresh Cup pod brewer has a menu that consist of scrolling menu entries that can be scanned through backward and...

Page 9: ...unction has been turned off This entry sets the time the machine will operate normally until the power save function is activated The user can choose 1 through 4 hours in 1 hour increments with the de...

Page 10: ...This entry sets the brew time in seconds for a 7 ounce cup of coffee with on off pulses The range is from 30 to 99 seconds with the default being 35 seconds EXIT Exit to Main Programming Menu Select W...

Page 11: ...ACE DRAIN PLUG ENSURE HOSE CLAMP IS TIGHT AND REPOSITION DRAIN HOSE BEFORE RE FILLING THE HOT WATER TANK SERVICING THE MACHINE The Fresh Cup machine has a modular Water Tank Assembly and Brew Mechanis...

Page 12: ...AL 1 LOOSEN 2 SCREWS THEN REMOVE COVER PANEL 3 SLIDE PANEL TO THE REAR OF THE MACHINE 2 REMOVE 2 SCREWS FROM REAR OF SIDE PANEL 4 LIFT PANEL UP AND RELEASE TOP FLANGE 5 SLIDE PANEL DOWN 6 SLIDE PANEL...

Page 13: ...ANK ONE ON BOTTOM OF PUMP BRACKET LOOSEN SCREWS TO REMOVE TOP BACK COVERS LOOSEN BUT DO NOT REMOVE THESE 2 SCREWS THEN LIFT PULL CONTROL BOARD BRACKET OUT OF MACHINE TO ACCESS TRANSFORMER REMOVE 2 6 3...

Page 14: ...246 U CUP SEAL RING 1 5 780257 UPPER BREW CHAMBER 61MM 1 6 780554 EJECT SLOPE CAM ASS Y 1 7 780528 MOLDED BUMP DISC PAD 1 8 780422 X 3 16 NYLON SPACER 1 9 780546 KICKER SLIDE WASHER 1 10 780254 X 1 ST...

Page 15: ...5 780253 TANK ONLY 1 6 773056 AIR PUMP POD 1 7 500396 LIQUID LEVEL PROBE BUSHING 2 8 151677 DUAL TEMP THERM PROBE 1 9 100149 ELBOW C X 1 8 NPT 1 10 704166 10 1700W 704161 10 1400W TANK HEATING ELEMEN...

Page 16: ...AL COMPONENTS 5 4 2 3 1 ITEM NEWCO PN DESCRIPTION QTY EA 1 780608 CONTROL BOARD BRACKET 1 2 110626 SWITCH DPST ON OFF 1 3 102383 SOLENOID FILL VALVE 1 4 105115 TRANSFORMER 120VAC 24VAC 1 5 780601 DISP...

Page 17: ...IVE MOTOR ERROR CHECK FOR JAM OR OBSTRUCTION IN BREW CHAMBER Message BOARD ERROR CONTROL BOARD WRITE ERROR REPLACE BOARD IF MESSAGE DOES NOT CLEAR PN 780602 Message FILL TIMEOUT ERROR WATER NOT REACHI...

Page 18: ...18 WIRING DIAGRAM...

Page 19: ...19...

Page 20: ...20 LEFT BLANK INTENTIONALLY...

Page 21: ...21 LEFT BLANK INTENTIONALLY...

Reviews: