2.10.14
7
Plumber’s Installation Instructions
CAUTION: Disconnect
Power to machine before proceeding with plumbing installation
.
1)
Attach water line to water filter, rear of machine.
2)
Flush water line before installing machine. Machine should be connected to COLD WATER LINE
ONLY.
3)
Water pressure should be at least 40 lbs. For less than a 25 ft run, use 1/4" copper tubing and connect to
1/2" or larger water line. For longer runs, use 3/8" copper tubing & connect to 1/2" or larger water line
and provide an adapter fitting for connection to the brewer.
A dedicated water line is necessary for
this machine. Minimum flow rate is 1GPM.
4)
If installed with saddle valve, the valve should have a minimum of 1/8" porthole for up to 25 ft run, and
5/16" porthole for over 25 ft runs.
5)
Manufacturer recommends connecting to copper tubing.
Electrical Hook-Up
WARNING
The Machine must be disconnected from the power source until specified in Installation
Instructions.
Determine the available on-site electrical requirements
Refer to Data Plate on the Machine, and local/national electrical codes to determine circuit
requirements.
CAUTION – Improper electrical installation will damage electronic components
.
Summary of Contents for Bistro 10
Page 32: ...2 10 14 32 Wiring Diagram...