background image

Liquid Coffee (LCD) Equipment

The power up procedures for all brewers with a tablet is listed inside the door of equipment on a label.

Any brewer that has a tablet will need the power switch left on to recharge tablet before it can be 

started back up again if tablet was left on and brewer power was lost.

Check inside the dispenser’s door for any error codes that may be displayed.  For touch screen models, errors 

will be visible on screen when powered up.  Common errors could include filling or heating errors after unit 

has been idle for prolonged periods.    E4 – Filling time out error, E3 – Heating time out error.  Power cycling 

will reset any error and attempt to resume normal operation.  Address water line issues / filter replacement 

prior to restarting machine.

If LCD Touch has been powered down without powering down tablet, the battery may have discharged.  It will 

require turning power switch on to allow battery to charge.  This may take 20-30 minutes to acquire enough 

charge for the tablet to power up.  

Tank can be drained and refilled using drain tubes.  LCD2 accessed through back panel, located below tank.  

LCD1 and Touch has a black plug on rear of machine attached to tube, it can be pulled out from back of 

machine.

External product hoses and internal pump assemblies may need to be sanitized as this product could spoil.  

Use open product at own risk after cleaning. It is reccomended to dispose of any used BIB product and load 

fresh product into dispenser.  The parts listed below will cover all the plumbing for liquid concentrate on LCD 

1, LCD 2 and LCD Touch.

Running the cleaning cycle will flush out any product still in the machine.  Running another cycle using a 

sanitizer will sanitize the lines.  If product ceases to pump through system, the pump head assembly may 

need to be replaced.  As a reminder, cleaning products to flush are not sanitizers, a separate solution using 

water and hypochlorite (bleach) can make a solution.  Make sure product being used has proper sodium 

hypochlorite ratio for sanitizing.  2 tablespoons per gallon of water is a sufficient ratio to sanitize.

Refer to sanitizing document for regular external cleaning to prevent surface contamination during normal 

operation.  70% alcohol wipes are sufficient.

120493 – pump head kit (pump head / tubing)

104155 – pump head (pump head kit including motor)

120422 – External Tube assembly (includes JG elbow and Scholle fitting) 12” assly.

773213 – Drip Tray (LCD2)

773214 – Grid for Drip tray (LCD 2)

121304 - DRIP TRAY,LCD-1

121305 - GRID,DRIP TRAY,LCD-1

Reviews: