For the Ozone feature, make certain all people, pets and plants are out of the area. 
Close all windows and doors and do not allow entry of the area.

Important Safety Information

OZONE WARNING

Standard safety precautions must always be followed to 
reduce the risk of fire, electric shock, and injury to persons, 
including the following: 
1.  Read these Instructions.
2.   Keep these Instructions.
3.   Heed all Warnings.
4.   Follow all Instructions.
5.   Do not use this apparatus in or near water.
6.   Clean only with a damp cloth.
7.   Do not block any of the ventilation openings. Install in 

accordance with the Manufacturer’s instructions.

8.   Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9.   Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug has 
two blades and a third grounding prong. The wide blade 
or the third prong are provided for your safety. When the 
provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus.

11.  Only use attachments/accessories specified by the 

manufacturer.

12.  Use only with a cart, stand, tripod, bracket, 

or table specified by the manufacturer, or 
sold with the apparatus. When a cart is 
used, use caution when moving the cart/
apparatus combination to avoid injury 
from tip-over.

13.  Unplug this apparatus during lightning 

storms or when unused for long periods of time.

14.  Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any 
way, such as power-supply cord or plug is damaged, liquid 
has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped.

15.  WARNING: To reduce the risk of fire or electric shock, 

do not expose this apparatus to rain or moisture. Do not 

place objects filled with water, such as a vase, on the 
apparatus.

16.  The AC mains plug is used as the power disconnect 

device and it should remain readily accessible and 
operable during intended use. In order to completely 
disconnect the apparatus from power, the mains plug 
should be completely removed from the AC outlet socket.

17.  Keep the cord out of heavy traffic areas. To avoid fire 

hazard, NEVER put the cord under rugs, near heat 
registers, radiators, stoves, or heaters.

18. DO NOT operate any generator with a damaged cord 

or plug, if motor fan fails to rotate, after the generator 
malfunctions, or if it has been dropped or damaged in any 
manner. Return generator to manufacturer or authorized 
repair facility for examination, electrical or mechanical 
adjustment, or repair.

19. Do not  leave the generator in use unattended around 

those requiring close supervision.

20.  WARNING! Always unplug the generator before moving 

it, cleaning, or whenever the generator is not in use. Be 
sure to pull by the plug and not the cord.

21.  This Hydroxyl Generator is for Indoor Use Only.
22.  Do not  attempt to repair or adjust any electrical or 

mechanical functions on this unit other than the UV 
bulbs and Carbon Filters. Doing so will void your 
warranty. All servicing should be performed by qualified 
personnel only.

23.  Do not place anything on top of generator.
24.  Do not  plug the cord in with wet hands: electric shock 

could result.

25.  NEVER use detergents, gasoline, glass cleaner, furniture 

polish, paint thinner or other household solvents to 
clean any part of the generator.

26.  See separate safety instructions (pages 4 and 5) for 

replacing the UV Lamp with mercury. 

27.  For General Ventilating Use Only. Do Not Use to Exhaust 

Hazardous or Explosive Materials and Vapors.

PLEASE READ AND SAVE THESE 

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for 852551003227

Page 1: ...t safety and maintenance information Keep these instructions for future reference These instructions contain important safety and operating information for your Newaire HO3 2500 Hydroxyl Ozone Generat...

Page 2: ...ies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received includin...

Page 3: ...ed or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock do...

Page 4: ...tip Keep the eyedropper at an angle to stop the mercury from rolling back out until you can put the mercury into the plastic bag Wrap tape sticky side out around your gloved fingers and carefully use...

Page 5: ...intensity of the problem With odors usually this unit can permanently eradicate them within a few days Is humidity good or bad to have with this unit Good The higher the treatment area s humidity the...

Page 6: ...f Controls Plastic End Cap HYDROXYL TIMER Knob CONTINUOUS Indicator OZONE TIMER Knob CAUTION OZONE ON Indicator Carrying Handle Power Switch OZONE Switch Plastic End Cap Fuse bottom of unit AC Cord bo...

Page 7: ...of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a...

Page 8: ...been reached the fan and UV bulbs will turn off w OZONE Can only be used when Hydroxyl Timer is set also and room must be empty of people pets and plants Set the desired ozone time using OZONE TIMER...

Page 9: ...the new carbon filter then replace the screen and plastic end cap x Re insert the two screws y Repeat for the other carbon filter located on the opposite side IMPORTANT The unit should never be opera...

Page 10: ...one of the 8 32 screws holding the finger guard in its place and loosen the opposing screw Rotate finger guard 180 so it is out of the way to access the UV Bulb area x Loosen both socket head screws...

Page 11: ...ign the bottom end of the UV bulb into the bottom recess V Reconnect the UV Lamp then reinsert socket head screws and gently tighten with 3 32 Allen key W Repeat process with the second UV lamp as the...

Page 12: ...s WARNING UV Bulbs MUST be disposed of properly see pages 4 and 5 for details on removing the mercury containing UV bulbs at Reinsert carbon filter metal retaining screen and plastic end cap then secu...

Page 13: ...rol panel Lift upper cabinet cover clear of the machine w Remove two screws one on each generator tube Loosen do not remove the screw in the middle of the tubes holding the titanium electrode to the w...

Page 14: ...e and electrode screws Replacement Parts Cleaning Fuses To order replacement parts contact your distributor or call 1 866 676 9663 for assistance Cleaning To clean use a damp soapy cloth for standard...

Page 15: ...66 676 9663 for service Generator is not performing well The life of the carbon filter may have been met or damaged replace both carbon filters see page 9 The life of the UV bulb may have been met or...

Page 16: ...ARRANTY REPAIR CENTER AT THE TIME REQUEST FOR REPAIR IS MADE EVIDENCE OF THE DATE OF PURCHASE AND DATES OF MAINTENANCE WORK MUST BE PROVIDED UPON REQUEST TRANSPORTATION COSTS SHALL BE BORNE BY THE PUR...

Page 17: ...QUEENAIRE TECHNOLOGIES INC 9483 State Highway 37 Ogdensburg NY 13669 www queenaire com...

Reviews: