NewAire 852551003227 User Manual Download Page 12

— 12 —

Replacing the UV Bulbs

WARNING:

•  UV Bulbs MUST be disposed of properly, see pages 4 and 5 for details on removing the mercury containing 

UV bulbs. 

at 

 

Reinsert carbon filter, metal retaining screen, and plastic end cap, then secure with retaining screws.

Summary of Contents for 852551003227

Page 1: ...t safety and maintenance information Keep these instructions for future reference These instructions contain important safety and operating information for your Newaire HO3 2500 Hydroxyl Ozone Generat...

Page 2: ...ies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received includin...

Page 3: ...ed or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock do...

Page 4: ...tip Keep the eyedropper at an angle to stop the mercury from rolling back out until you can put the mercury into the plastic bag Wrap tape sticky side out around your gloved fingers and carefully use...

Page 5: ...intensity of the problem With odors usually this unit can permanently eradicate them within a few days Is humidity good or bad to have with this unit Good The higher the treatment area s humidity the...

Page 6: ...f Controls Plastic End Cap HYDROXYL TIMER Knob CONTINUOUS Indicator OZONE TIMER Knob CAUTION OZONE ON Indicator Carrying Handle Power Switch OZONE Switch Plastic End Cap Fuse bottom of unit AC Cord bo...

Page 7: ...of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a...

Page 8: ...been reached the fan and UV bulbs will turn off w OZONE Can only be used when Hydroxyl Timer is set also and room must be empty of people pets and plants Set the desired ozone time using OZONE TIMER...

Page 9: ...the new carbon filter then replace the screen and plastic end cap x Re insert the two screws y Repeat for the other carbon filter located on the opposite side IMPORTANT The unit should never be opera...

Page 10: ...one of the 8 32 screws holding the finger guard in its place and loosen the opposing screw Rotate finger guard 180 so it is out of the way to access the UV Bulb area x Loosen both socket head screws...

Page 11: ...ign the bottom end of the UV bulb into the bottom recess V Reconnect the UV Lamp then reinsert socket head screws and gently tighten with 3 32 Allen key W Repeat process with the second UV lamp as the...

Page 12: ...s WARNING UV Bulbs MUST be disposed of properly see pages 4 and 5 for details on removing the mercury containing UV bulbs at Reinsert carbon filter metal retaining screen and plastic end cap then secu...

Page 13: ...rol panel Lift upper cabinet cover clear of the machine w Remove two screws one on each generator tube Loosen do not remove the screw in the middle of the tubes holding the titanium electrode to the w...

Page 14: ...e and electrode screws Replacement Parts Cleaning Fuses To order replacement parts contact your distributor or call 1 866 676 9663 for assistance Cleaning To clean use a damp soapy cloth for standard...

Page 15: ...66 676 9663 for service Generator is not performing well The life of the carbon filter may have been met or damaged replace both carbon filters see page 9 The life of the UV bulb may have been met or...

Page 16: ...ARRANTY REPAIR CENTER AT THE TIME REQUEST FOR REPAIR IS MADE EVIDENCE OF THE DATE OF PURCHASE AND DATES OF MAINTENANCE WORK MUST BE PROVIDED UPON REQUEST TRANSPORTATION COSTS SHALL BE BORNE BY THE PUR...

Page 17: ...QUEENAIRE TECHNOLOGIES INC 9483 State Highway 37 Ogdensburg NY 13669 www queenaire com...

Reviews: