NewAire 852551003227 User Manual Download Page 2

— 2 —

Important Safety Information .................................................................................................................. 2
Ozone Warning ........................................................................................................................................ 3
Handling and Disposal of Mercury .......................................................................................................... 4
FAQs ........................................................................................................................................................ 5
Location of Controls ................................................................................................................................ 6
Operation ................................................................................................................................................. 7
Replacing the Carbon Filters ................................................................................................................... 9
Replacing the UV Bulbs ........................................................................................................................ 10
Replacing the Generator Tubes ............................................................................................................. 13
Fuses ..................................................................................................................................................... 14
Cleaning ................................................................................................................................................ 14
Replacement Parts ................................................................................................................................ 14
Specifications ........................................................................................................................................ 15 
Troubleshooting ..................................................................................................................................... 15
Limited Warranty ................................................................................................................................... 16

Table of Contents

Important Safety Information

DANGEROUS  VOLTAGE:

  The  lightning  flash  with 

arrowhead  symbol  within  an  equilateral  triangle  is 
intended to alert the user to the presence of uninsulated 
dangerous voltage within the product’s enclosure that 
may be of sufficient magnitude to constitute a risk of 
electric shock to persons.

WARNING:

 TO PREVENT FIRE OR SHOCK HAZARD, DO NOT 

EXPOSE THIS UNIT TO RAIN OR MOISTURE.

WARNING:

 DO NOT look directly at UV bulbs.

WARNING:

 Use this Hydroxyl Generator only for its intended 

purpose as described in this Owner’s Manual.

ATTENTION:

 The exclamation point within an equilateral 

triangle is intended to alert the user to the presence 
of  important  operating  and  maintenance  (servicing) 
instructions in the literature accompanying this product.

FCC  WARNING:

  This  equipment  may  generate  or  use  radio 

frequency  energy.  Changes  or  modifications  to  this  equipment 

may  cause  harmful  interference  unless  the  modifications  are 

expressly approved in the instruction manual. The user could lose 

the authority to operate this equipment if an unauthorized change 

or modification is made.
This device complies with part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause 

undesired operation.

NOTE:

 This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection 

against  harmful  interference  in  a  residential  installation.  This 

equipment generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for 

help.

INDUSTRY CANADA NOTICE:

This device complies with Industry Canada Iicense-exempt RSS 
standard(s). Operation is subject to the following two conditions: 
1. This device may not cause interference, and 
2. This device must accept any interference, including interference 

that may cause undesired operation of the device.

CAN ICES-3(B)/NMB-3(B)

Summary of Contents for 852551003227

Page 1: ...t safety and maintenance information Keep these instructions for future reference These instructions contain important safety and operating information for your Newaire HO3 2500 Hydroxyl Ozone Generat...

Page 2: ...ies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received includin...

Page 3: ...ed or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock do...

Page 4: ...tip Keep the eyedropper at an angle to stop the mercury from rolling back out until you can put the mercury into the plastic bag Wrap tape sticky side out around your gloved fingers and carefully use...

Page 5: ...intensity of the problem With odors usually this unit can permanently eradicate them within a few days Is humidity good or bad to have with this unit Good The higher the treatment area s humidity the...

Page 6: ...f Controls Plastic End Cap HYDROXYL TIMER Knob CONTINUOUS Indicator OZONE TIMER Knob CAUTION OZONE ON Indicator Carrying Handle Power Switch OZONE Switch Plastic End Cap Fuse bottom of unit AC Cord bo...

Page 7: ...of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a...

Page 8: ...been reached the fan and UV bulbs will turn off w OZONE Can only be used when Hydroxyl Timer is set also and room must be empty of people pets and plants Set the desired ozone time using OZONE TIMER...

Page 9: ...the new carbon filter then replace the screen and plastic end cap x Re insert the two screws y Repeat for the other carbon filter located on the opposite side IMPORTANT The unit should never be opera...

Page 10: ...one of the 8 32 screws holding the finger guard in its place and loosen the opposing screw Rotate finger guard 180 so it is out of the way to access the UV Bulb area x Loosen both socket head screws...

Page 11: ...ign the bottom end of the UV bulb into the bottom recess V Reconnect the UV Lamp then reinsert socket head screws and gently tighten with 3 32 Allen key W Repeat process with the second UV lamp as the...

Page 12: ...s WARNING UV Bulbs MUST be disposed of properly see pages 4 and 5 for details on removing the mercury containing UV bulbs at Reinsert carbon filter metal retaining screen and plastic end cap then secu...

Page 13: ...rol panel Lift upper cabinet cover clear of the machine w Remove two screws one on each generator tube Loosen do not remove the screw in the middle of the tubes holding the titanium electrode to the w...

Page 14: ...e and electrode screws Replacement Parts Cleaning Fuses To order replacement parts contact your distributor or call 1 866 676 9663 for assistance Cleaning To clean use a damp soapy cloth for standard...

Page 15: ...66 676 9663 for service Generator is not performing well The life of the carbon filter may have been met or damaged replace both carbon filters see page 9 The life of the UV bulb may have been met or...

Page 16: ...ARRANTY REPAIR CENTER AT THE TIME REQUEST FOR REPAIR IS MADE EVIDENCE OF THE DATE OF PURCHASE AND DATES OF MAINTENANCE WORK MUST BE PROVIDED UPON REQUEST TRANSPORTATION COSTS SHALL BE BORNE BY THE PUR...

Page 17: ...QUEENAIRE TECHNOLOGIES INC 9483 State Highway 37 Ogdensburg NY 13669 www queenaire com...

Reviews: