COOLER/HUMIDIFIER BUTTON 

 

Cooler/Humidifier 

Indicator 

After the desired fan speed has been selected, press the 
COOLER/HUMIDIFIER button to activate the 
cooling/humidifying function. This powers the water 
pump, cools the air and adds moisture to your air at the 
same time. The blue cooling icon will also be visible on 
the display panel. 

Please note that if the initial fan speed is set to 3, the unit will revert back to 
the second speed setting for 5 minutes. After 5 minutes, the unit will 
automatically switch to the third fan speed. This allows the cooling pad to 
absorb sufficient water for optimized cooling. The cooler will not revert back to 
other speeds if the initial fan speed was set to either 1 or 2. 

MODE BUTTON 

The NEC500SI00 has 2 different automatic airflow modes. Setting the airflow 
mode is optional. 

To set the airflow mode, press the MODE button. 

 

 

Natural 

Mode 

Natural Mode

 

 Indicated by the palm tree icon on the display 

panel, this setting will adjust the airflow speed between low, 
medium and high. 

 

Sleep Mode 

Sleep Mode

 

 Indicated by the moon icon on the display 

panel, this setting will gradually lower the speed at different 
intervals, depending on the selected fan speed. If the fan 
speed is set to 3, the cooler will run for 30 minutes on high 
speed, 30 minutes on medium speed, and then continue to 
operate on low speed. If the fan speed is set to 2, the cooler 
will run for 30 minutes on medium speed and then continue 
to operate on low speed. If the fan speed is set to 1, the 
cooler will continuously run on low speed. 

Summary of Contents for NEC500SI00

Page 1: ...Manual v1 0 Evaporative Air Cooler SKU NEC500SI00...

Page 2: ...The Remote Control 13 Cleaning and Maintenance Attention 14 Troubleshooting 17 Limited Manufacturer s Warranty 18 SPECIFICATIONS MODEL NO NEC500SI00 PRODUCT DIMENSIONS 16 1 W x 11 1 D x 35 0 H PRODUCT...

Page 3: ...ffers Registering your product information online is safe secure and takes less than 2 minutes to complete 0 Alternatively we recommend you attach a copy of your sales receipt below and record the fol...

Page 4: ...and pulling it from the power outlet Do not disconnect the power supply by pulling on the evaporative cooler s power cord Avoid contact with any of the evaporative cooler s moving parts Place the eva...

Page 5: ...product contains a lithium button coin cell battery If a new or used lithium button coin cell battery is swallowed or enters the body it can cause severe internal burns and can lead to death in as lit...

Page 6: ...6 newair com PARTS LIST Check to insure the following parts are included with your product Evaporative cooler Ice Pack Remote control CR2032 3V battery...

Page 7: ...rooms patios and offices Sleek modern design makes it an attractive addition to your home High efficiency rigid cooling pad holds more water Removable water tank makes refilling and emptying easy Powe...

Page 8: ...the first time we recommend cleaning the tank with a solution of warm water and light detergent FILLING THE WATER TANK 1 Remove the water tank by turning the water tank knob counterclockwise 90 degre...

Page 9: ...e the ice pack in the freezer until frozen Do not open the ice pack or ingest its contents 2 Put the ice pack into one of the water tank s chambers 3 The ice pack is not necessary for operation but wi...

Page 10: ...cooler will be in standby mode at this time ON SPEED OFF BUTTONS 1 Press the ON SPEED button to turn on the evaporative cooler 2 To adjust the fan speed press ON SPEED button again until your desired...

Page 11: ...if the initial fan speed was set to either 1 or 2 MODE BUTTON The NEC500SI00 has 2 different automatic airflow modes Setting the airflow mode is optional To set the airflow mode press the MODE button...

Page 12: ...press of this button will add 0 5 hours to the set time 2 The set time will be indicated in the middle of the display panel SWING BUTTON Swing Indicator To activate the oscillation feature press the...

Page 13: ...te control aim it at the unit s remote control receiver and select one of the functions on the remote control The effective distance is about 24 ON SPEED Power ON and adjusts speed OFF Power OFF TIMER...

Page 14: ...supply CLEANING THE DUST FILTER COOLING PAD To prevent the cooling pad and filter from becoming clogged with dust mineral deposits and other buildup we recommend that it be cleaned at least once a mon...

Page 15: ...buildup can affect the performance of the cooler s water pump To prevent malfunctions clean the pump and internal tubing with a calcium and lime cleaning product such as CLR at least once a season 1...

Page 16: ...r to other parts of the cooler 6 Rinse the tank and fill it with clean water Run it for several minutes without the cooling pad in place to ensure the cleaning solution has been rinsed away 7 Replace...

Page 17: ...ater The cooler humidifier button was not pressed Press the COOLER HUMIDIFER button The pump is defective Contact customer service if there is an issue with the water pump The unit does not sufficient...

Page 18: ...supply such as low voltage defective household wiring or inadequate fuses Accident alteration misuse or abuse of the appliance such as using non approved accessories inadequate air circulation in the...

Reviews: