9
3.
SMS INPUT CONFIGURATION
Name cell:
SMSINPUTCONFIG
Number field cell:
0000000000000000
Comment:
1st number = SMS about Input No1
2nd number = SMS about Input No2
3rd number = SMS about Input No3
4th number = SMS about Input No4
5th number = SMS about Input No5
6th number = SMS about Input No6
7th number = SMS about Input No7
8tht number = SMS about Input No8
9th number = SMS about Input No9
10th number = SMS about Input No10
11th number = SMS about Input No11
12th number = SMS about Input No12
13th number = SMS about Input No13
14th number = SMS about Input No14
15th number = SMS about Input No15
16th number = SMS about Input No16
When Input is triggered, controller will send SMS to Admin number
"0" =
deny
. "1" =
send SMS on connection and disconnection
, "2" =
send SMS on connection
NO,
"3" =
send SMS disconnect NC ,
Alarm mode settings
- “4”=Full control Inputs
(doors, windows, motion sensors), “5”= external perimeter control beams
4.
ENGINEER SERVICE NUMBER
Name cell:
SERVICE
Number field cell
:+353863310929
Comment:
Telephone number Service engineer :(
can only do remote system programming
)
* By default is Manufacturer 353863310929 but you can change it to your service
engineer number
5.
CONFIGURATION TIME INTERVALS
Name cell:
TIMECONFIG
Number field cell:
15251001
Comment:
1st and 2nd number =
Intercom dial time to Admin number in sec. (01-99sec)
3rd and 4th number =
talk time with a door intercom when the call has been answered in sec.
(01-99sec)
5th number =
Output
relay off delay in sec (1-9) on short call relay control mode
6th number =
Cal credit balance checking in hours. (0-9h) (0-do not check)
7th and 8th number =
Siren working time in alarm mode (01-99sec), Unused in Gate
Intercom/Opener mode.