8
1.
SYSTEM WORK CONFIGURATION
Name cell:
WORKCONFIG
Number field cell:
110000
Comment:
1st number =
permission to control relays, if any relay is switched On.
"0" =
deny
. "1" =
allow
;
2nd number =
control relays via SMS.
"0" =
all users
. "1" =
only
a
dministrator
;
3rd number =
Dial to ADMIN if any Inputs triggered.
"0" =
deny
. "1" =
allow
;
4th number =
Inputs/Outputs Extension module up to 16 Inputs
.
"0" =
not connected
. "1" =
connected;
5th number =
controller operating mode
.
"0" =
Gate Intercom/Opener mode
. "1"
Alarm system mode
;
6th number =
Alarm Siren activation (in Alarm mode only).
"0" =
only when Alarm
. "1" =
short beep, Arm/Disarm mode (
not use in Intercom mode
)
2.
SYSTEM SMS CONFIGURATION
Name cell:
SMSCONFIG
Number field cell:
010010
Comment:
1st number = SMS about power On/Off.
"0" =
deny
. "1" =
allow
;
2nd number =
sending SMS to Administrator (ADMIN) when calling
unauthorized person to system
"0" =
deny
. "1" =
allow
;
3rd number =
SMS about Relay On/Off activation
.
"0" =
deny
. "1" =
allow anyway
; "2" =
allow if Relay On
; "3" =
allow if Relay Off;
4th number =
send
SMS about external inputs status
"0" =
send to admin
. "1" =
send to the admin and Users;
5th number =
call credits limit balance information SMS
"0" =
send to
administrator and Service engineer
. "1" =
send to any number by request;
6th number =
response SMS to manage security reaction (not use in Intercom mode)
"0" =
only who arm/disarm the alarm
. "1" =
who arm/disarm alarm and send copy SMS to
the Admin number also
;