12
SERVICE Query content configuration of cells:
Format SMS query:
< name > <?>
Example:
WORKCONFIG ?
Example:
SMSCONFIG ?
Example:
SMSINPUTCONFIG ?
Example:
TIMECONFIG ?
Format SMS:
< name > < <:> cell data >
Example:
WORKCONFIG:0001
Example:
SMSCONFIG:00101
Example:
SMSINPUTCONFIG:0000110101000000
Example:
TIMECONFIG:152512
Controller INPUT name settings
:
If alarm Input is NC and disconnected loop, controller send alarm SMS with text which you
can change by your request:
Format SMS to setup text:
<TXT> > < Input number><:><new text max20
Example:
SMS text for Input1 connect TXT I1ON: Alarm temperature!
SMS text for Input1 disconnect TXT I1OFF: Normal temperature
SMS text for Input8 connect TXT I8ON: Alarm! Door OPEN!
SMS text for Input1 disconnect TXT I8OFF:Alarm message 1 OFF
SERVICE Replace the contents of the configuration:
(to replace just edit it and send SMS , came in response to a query)
Format SMS to replace:
< name > < <:> cell data >
Example:
WORKCONFIG :1001
Example:
SMSCONFIG :11101
Example:
SMSINPUTCONFIG :0101110000000000
Example:
TIMECONFIG :152584
Format response SMS:
Write config SIM is successful!
SMS about the call to the module is not listed in a Subscriber SIM card
:
If User not from controller address book will call in to the system, controller take dialler
number and resend to Admin number.
Format SMS:
The attempt is not authorized 353509631994