INTRODUCTION
Pipe thread fitting torque
Before installing and tightening pipe fittings, clean the
threads with a clean solvent or Loctite cleaner and apply
sealant
L
OCTITE
® 567™ PST P
IPE
S
EALANT
for all fittings
including stainless steel or
L
OCTITE
® 565™ PST
for
most metal fittings. For high filtration/zero contamination
systems use
L
OCTITE
® 545™
.
Thread size
Torque (maximum)
1/8-27
13 N·m
(
10 lb ft
)
1/4-18
16 N·m
(
12 lb ft
)
3/8-18
22 N·m
(
16 lb ft
)
1/2-14
41 N·m
(
30 lb ft
)
3/4-14
54 N·m
(
40 lb ft
)
Installation of ORFS (O-Ring Flat Seal fit-
tings)
When installing ORFS fittings thoroughly clean both flat
surfaces of the fittings
(1)
and lubricate the O-ring
(2)
with
light oil. Make sure both surfaces are aligned properly.
Torque the fitting to specified torque listed throughout the
repair manual.
NOTICE:
If the fitting surfaces are not properly cleaned,
the O-ring will not seal properly. If the fitting surfaces are
not properly aligned, the fittings may be damaged and will
not seal properly.
NOTICE:
Always use genuine factory replacement oils
and filters to ensure proper lubrication and filtration of en-
gine and hydraulic system oils.
The use of proper oils, grease, and keeping the hydraulic
system clean will extend machine and component life.
50011183
2
47770440A 15/02/2017
19