GENERAL
E485C
W5-1-19
Failure diagnosis procedures
JP30ZDE010301002
1.
Display of failure code
(1)
If the system has an error, the failure code is displayed on the multiple display of cluster gauge.
2.
Deletion method of past failure
(1)
To delete past failures of the engine ECU, use HinoDX on
the PC. (Refer to "HinoDX operation manual".)
3.
Deletion of cluster gauge past failure
(1)
Turn "ON" the starter switch during pushing the buzzer
stop switch.
(2)
When pushing the enter key 3 times during pushing the
buzzer stop switch, the failure history mode is displayed.
(3)
Press work mode selecting switch and the buzzer stop
switch at the same time for 10 seconds or more.
(4)
When the display shows "No error", deletion is
completed.
(5)
Turn "OFF" the starter switch.
SAPH30ZDE0100027
SAPH30ZDE0100028
SAPH30ZDE0100029