background image

 

New Cosmos USA, Inc. 
Natural Gas Alarm  
806NIT 

 

Professional Installation 
Guide  

This Gas Alarm is designed to 
be installed and cleaned 
exclusively by authorized 
professionals.  Users should 
not install or clean the gas 
alarm themselves.

  This guide is 

intended for professional use 
only. 

Selecting location for 
installation 

 

NOTICE 

 

Installation in an improper location 
can affect the sensitive electronic 
components in this Gas Alarm. 

 

Improper placement can prevent 
detection of methane.  

 

Place out of reach of children.  

Gas Alarm should be installed by attaching it 
to a pipe or, if a suitable pipe is unavailable, 
to a location on a wall that is

 

Between 4 to 12 inches (0.1 to 0.3 
meters) from the ceiling. 

 

In an area where it will not be impeded 
by items hanging from or near the 
ceiling such as curtains, drapes, ceiling 
fans.  

 

At least 5 feet (1.5 meters) from cooking 
appliance or cooktop hood. 

 

At least 10 feet (3 meters) from gas 
appliances. 

Gas Alarm should NOT be installed: 

 

In the peak of a cathedral ceiling.  

 

Directly above or near sources of water 

or humidity such as a sink, cooktop, 
dishwasher or a shower. 

 

Next to a door or window. 

 

Next to a ventilation fan. 

 

Near a room return or HVAC duct. 

 

In an area where the temperature will 
drop below 32°F (0°C) or exceed 122°F 
(50°C). 

 

In an area that is dusty or dirty. 

 

In an area where organic solvents exist 
or silicone vapors. 

 

In a damp or very humid location, such 
as a bathroom. 

 

Outside. 

Installing the battery 

 

DANGER 

– SHOCK  

Do NOT remove the plastic wrap 
surrounding the battery pack. Doing 
so may cause electrical short or 
shock. 

 

NOTICE 

Gas Alarm uses type of battery that 
is not available in retail. Contact 
your gas utility if replacement 
battery needed. 

After installing battery, test the Gas 
Alarm following instructions in 
Troubleshooting Guide. 

 
To reinstall the included battery or 
install a new battery you received from 
your gas utility: 

  Open the battery cover on the back of 

the detector. This cover slides out of 
place. To open, place both thumbs on 
the back of the battery cover where the 
battery cover hooks snap into place. 

  Push down where the battery cover 

snaps into place with your thumbs and 
slide the cover out. Some force is 
required. 

 

 

 

 

 

 

 

 

 

 

 

  Connect the included lithium battery by 

inserting the battery harness connector 
into the product as shown in the diagram 
below. Do NOT remove the plastic wrap 
surrounding the battery pack. 

 

 

 

 

 

 

  The battery connector has a large notch 

on it that faces up when installed 
correctly. There is only one way in which 
the connector can be installed. A small 
portion of the connector will be exposed 
when connected properly. 

Mounting the Gas Alarm 

 

NOTICE 

After mounting the Gas Alarm, test it 
following instructions in 
Troubleshooting Guide. 

If possible, mount the Gas Alarm to a 
pipe meeting the criteria discussed in the 
“Selecting location for installation” 
section.  To mount to a pipe: 

(1)  Pass a cable tie through the hole at 

the top of the Gas Alarm. 

 

 

 

(2)  Wrap the cable tie around the pipe 

and tie off. 

If mounting to a pipe is not feasible, mount 
the detector to a wall. 

(1)  Choose a location on the wall 

between 4 inches (0.1 meters) to 12 
inches (0.3 meters) from the ceiling. 
Make a mark in the Mounting Tab of 
the Gas Alarm where you will drill 
the mounting hole. 

(2) 

Use a 3/16” (5 mm) drill bit to drill 
the mounting hole and insert 
included anchor. 

(3)  Tighten the screw into the anchor 

until the screwhead is about 3/16   
inch (5 mm) away from the wall, 
leaving enough space for the 
Mounting Tab. 

(4)  Hang the Mounting Tab on the 

screw. 

 

(5) 

Lightly tighten the screw to secure 
the Gas Alarm. 

 

Summary of Contents for DeNova Detect 806NIT

Page 1: ...or Network or power outages may prevent your gas utility from receiving or processing automated notifications from your Gas Alarm including notifications related to gas leak alarms Always follow these instructions without relying on such automated notifications This Gas Alarm will reach its end of service life in approximately 6 years from the date of installation Contact your gas utility for repl...

Page 2: ...ully in the event that the natural gas leak alarm activates Never ignore any natural gas leak alarms EVACUATE IMMEDIATELY and take others with you Do NOT use a phone light a match or turn on or off any light switches flashlights or appliances Doing so could IGNITE a FIRE or EXPLOSION CALL 911 once you are safely outside the premises Do NOT re enter until told to do so by authorities DANGER EXPLOSI...

Page 3: ...sehold cleaning agents ammonia based cleaners paints varnishes aerosol sprays including compressed gas dusters or any other chemical on or near this Gas Alarm Specifications Contact Details New Cosmos USA Inc 650 Warrenville Rd Suite 101 Lisle IL 60532 Tel 847 749 3064 Conforming standards UL standard UL1484 FCC Certified Detection principle MEMS hot wire semiconductor sensor Target gas Methane ga...

Page 4: ...t mode and the green LED will flash 3 times per second for as long as you are in communications test mode Once in communications test mode press the test button additional times to test whether the detector is communicating normally with your gas utility s systems able to properly transmit detector error signals and able to properly transmit a low battery signal Success will be indicated as follow...

Page 5: ...ent battery needed After installing battery test the Gas Alarm following instructions in Troubleshooting Guide To reinstall the included battery or install a new battery you received from your gas utility Open the battery cover on the back of the detector This cover slides out of place To open place both thumbs on the back of the battery cover where the battery cover hooks snap into place Push dow...

Reviews: