- 18 -
DIP Switches
Item
Component
Description/function
1
IP address type switch
Switches the IP address type between “DY” and “ST”.
DY: Dynamic IP address (DHCP)
ST: Static IP address
2
Mode change switch
Switches the communication mode between “ETHERNET”
and “RS485”.
ETHERNET: Modbus TCP (Ethernet)
RS485: Modbus RTU (RS-485)
3
Address setting switches
(8 places)
Sets the address (unit ID) for this product.
Settable range: 1 (0000 0001) to 254 (1111 1110).
The unit ID set here will also serve as the 4th value of the IP
address when Modbus TCP (Ethernet) is selected with the
mode change switch.*
* If the 4th value is set to 0 (0000 0000) with the address setting switches, it will be superseded by
the value set by a web browser.
The DIP switches are accessible when the address plate is removed. To remove the
address plate, refer to 7-1. “Operation Procedure” of the PS-7-M series gas
detector’s instruction manual.
With address plate removed
NOTE
Address plate