3 . 2

 

–   P o w e r   s u p p l y   f o r   u s e  

MAGNETO  BIOLIFE  can  be  battery  operated  or  use  230V,  connecting  the  power 
supply unit to the device and a normal electricity socket. 

 

3 . 3

 

–   S w i t c h i n g   o n   t h e   d e v i c e  

To switch on MAGNETO BIOLIFE Keep the 

(I) ON/OFF

 key pressed

 The display 

shows the name of the device followed by the program. 

 

3 . 4

 

–   S e l e c t   t h e   p r o g r a m  

 

Choose the desired program with the +/- keys (see Programs Table);  

 
 

Programs Table 

 

PROGRAMS 

No. 

FREQ (Hz) 

DURATION  

INTENS. G 

 

STIM 

75 

4h 

15 

KNEE/ELBOW 

70 

1.5h 

20 

SHOULDER 

65 

2h 

20 

BUNION 

75 

4h 

15 

ANKLE 

70 

1.5h 

20 

WRIST 

80 

1h 

15 

3 . 5

 

–   S t a r t i n g   s t i m u l a t i o n  

 

When the desired program appears on the display, press the START button. Once the 
program is activated on the display, the TIMER appears to indicate the remaining time 

and at the bottom of the display this signal 

will appear to indicate treatment has 

started. 

 

3 . 6

 

–   T i m e r   A d j u s t m e n t  

 

You  can increase  the  duration  of  the  program  (Timer)  to  prolong  therapy  by  some 
hours or for night applications, up to a maximum of eight hours. To adjust the timer 
when a program is in progress, use the + and - keys  

 

ATTENTION:

 for the duration of the sessions, follow the instructions of the doctor 

who prescribed magnetotherapy, in particular for applications from 4 to 8 hours. 

 

3 . 7

 

–   S t o p / t e r m i n a t e   t h e r a p y  

 

If  you  want  to  stop  therapy  before the  end,  press  the  STOP  key:  once  to  pause  (to 
continue press START). 
 
 
 

 

Summary of Contents for MAGNETO BIOLIFE

Page 1: ...39 0545 32019 Telefax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is the property of New Age Italia srl All rights reserved It is forbidden to copy and reproduce i...

Page 2: ...Rev 01 on 06 05 16 2 24...

Page 3: ...Rev 01 on 06 05 16 3 24...

Page 4: ...Select the program 9 3 5 Starting stimulation 9 3 6 Timer Adjustment 9 3 7 Stop terminate therapy 9 3 8 Switch off device 10 3 9 Symbols on the display 10 Cap 4 APPLICATIONS 10 4 1 Therapy sessions 1...

Page 5: ...S 16 8 1 Power supply 16 8 2 Output features 16 8 3 Other features 16 Cap 9 SYMBOLS 17 Cap 10 STANDARD EQUIPMENT AND ACCESSORIES 17 10 1 Standard equipment 17 10 2 Accessories and consumable material...

Page 6: ...easy use makes the product extremely innovative in the electromedical devices sector 1 2 W h y u s e M A G N E T O B I O L I F E MAGNETO BIOLIFE enables application of magnetic fields with beneficial...

Page 7: ...udoarthrosis arthrosis arthritis inflammatory and degenerative arthropathies oedema algodystrophy tendinitis You are advised to consult a doctor for diagnosis and control of the therapy 2 2 C o n t r...

Page 8: ...re applying magnetotherapy follow the instructions carefully of the doctor prescribing magnetotherapy 3 1 C o n n e c t i o n a n d a p p l i c a t i o n Connect the cable of the applicator to the dev...

Page 9: ...r t i n g s t i m u l a t i o n When the desired program appears on the display press the START button Once the program is activated on the display the TIMER appears to indicate the remaining time an...

Page 10: ...g to medical prescription Applications can be carried out every day with the most suitable program for the patient s pathology until the problem is healed or significantly reduced if necessary 2 3 app...

Page 11: ...Rev 01 on 20 01 2017 11 24 EXAMPLES OF APPLICATIONS SHOULDER APPLICATION ELBOW APPLICATION KNEE APPLICATION ANKLE APPLICATION FOOT APPLICATION WRIST APPLICATION...

Page 12: ...When the flat battery status is signalled proceed with the recharge cycle To safeguard the battery MAGNETO BIOLIFE is equipped with an auto power off system 5 2 C h a r g e To charge the MAGNETO BIOL...

Page 13: ...ry connections which would destroy the electronic circuits 5 5 P r e c a u t i o n s f o r u s e 1 Do not throw the old battery in ordinary waste but give it to authorised staff for its disposal 2 Do...

Page 14: ...mechanical stress e g serious fall the device was subjected to strong overheating e g if left near intense heat sources if you doubt liquids can penetrate inside the power supply unit the casing and...

Page 15: ...ical device as this may be hazardous for the patient and the device itself The device performs as specified only if surroundings are kept at a temperature between 5 and 40 C and with humidity less tha...

Page 16: ...otection rating IP20 Safety rating for use near inflammable anaesthetic gases AP or APG Device operation continuous Manufactured in compliance with the following regulations EN 60601 1 2007 Electromed...

Page 17: ...DIRECTIVE EEC 93 42 AMENDED BY 2007 47 EC WASTE DISPOSAL ACCORDING TO DIRECTIVE 2002 96 ECC AND 2003 108EEC Cap 10 STANDARD EQUIPMENT AND ACCESSORIES 1 0 1 S t a n d a r d e q u i p m e n t Device App...

Page 18: ...t applicable Voltage fluctuations emission flicker IEC 61000 3 3 Not applicable Table 202 Declaration Electromagnetic immunity Guidance and manufacturer s declaration electromagnetic immunity The MAGN...

Page 19: ...ed RF transmitters force fields As determined by research on an electromagnetic site a it must be lower than the conformity threshold of each frequency range b Interference may manifest near devices m...

Page 20: ...olled The user must avoid electromagnetic interference by maintaining a minimum distance between portable and mobile telecommunications equipment and the MAGNETO BIOLIFE device as recommended above ba...

Page 21: ...B Gialanella G D alessandro R Santoro Terapia fisica pratica ED Marrapese Roma 1997 Vasta Manuale pratico illustrato di terapia fisica ED Marrapese Roma 1998 Cisari G Severini Fisioterapia clinica pr...

Reviews: