![Neutec MIDI00SP Operator'S Handbook Manual Download Page 20](http://html1.mh-extra.com/html/neutec/midi00sp/midi00sp_operators-handbook-manual_1676425020.webp)
Operator’s Handbook
Ca
pi
tol
o:
Use
20
Correcting the alignment
Take great care to avoid inadvertently activating laser emission when performing realignment operations.
With the device in standby, locate the screws close to the cone
slide holder as shown in the illustration.
Never touch the screw no. 3, the one between the other two
screws without a guide. This screw has been placed there by the
manufacturer. Using the 3 mm hex key, loosen screws 1 and 2.
•
Turning screw no. 1 moves the welding point
horizontally.
•
Turning screw no. 2 moves the welding point
vertically.
Use slight movements and small shots on a piece of metal to
verify the correct positioning of the crosshairs. Continue until the
crosshairs coincide perfectly with the welding spot.
The screws for the alignment have brass guides to make them
easier to identify.
To facilitate the alignment procedure, the crosshairs bear the symbol
▲,
which indicates the highest point. make sure this
symbol is pointed upwards and complete the alignment as described above.
Only use the viewing window to inspect the inside of the welding chamber, it is a good rule to put the device in standby before
adjusting the screws to prevent accidentally activating the laser.
Repairs
Repairs should only be made in the event of an anomaly, see the chapter
Diagnostics
for more information.
Repairs should only be performed by Neutec USA personnel or personnel it has authorized.
Recommendations
The following recommendations will optimize the efficiency of the device:
•
The device should be stored in a location that is not too hot and away from heat sources; the higher the temperature of the environment,
the lower the efficiency of the cooling circuit/heat exchanger.
•
Keep away from equipment that produces moisture or dust, such as sand blasters, vaporizers, etc.
•
Follow the directions in the manual, and read the sections on safety and maintenance.
•
Use only original spare parts specified in this manual.
•
Only use deionized water as a cooling liquid, the use of water or liquids different from that indicated may affect device operation.
•
Ensure that safety devices are working properly.
1