Electrical connections
Make sure that the power outlet is appropriate before connecting the power cable. Check the information on the plate located on the back of the
machine for more information.
Make sure that the electrical outlet of the mains supply has a Schuko socket; the welder absorbs 10A at 230Vac.
Install a general duty safety switch upstream of the device's cable connection with the power grid.
The safety switch should be used in combination with a surge protection device equipped with an emergency shut-off switch (SPD).
The features of these devices should be designed to meet the regulations of the country where the device is being installed, and
sized per the specifications of the device.
Power supply tolerances
•
Voltage at
±
10% of the rated voltage.
•
Frequency:
±
1% of the rated voltage for continuous use
±
2% of the rated voltage for short periods
•
Harmonic distortion for the sum of the second to fifth harmonics no more than 10% of the total voltage RMS between live conductors.
Further distortion is permitted for the sum of the sixth to thirtieth harmonics up to 2% on the total RMS between live conductors.
•
The voltage pulses should be no longer than 1.5 ms with a rise/fall time of between 500ms and
500μs
and a peak value that does not
exceed 200% of the effective value of the nominal supply voltage.
•
The power supply should not be interrupted nor go to zero for longer than 3ms at any moment during power. There should be no
more than 1s between two successive interruptions
•
The voltage dips should not exceed 20% of the peak voltage for more than one cycle. There should be no more than 1s between
voltage dips.
Device specifications
Technical specifications
Power supply:
110V–230V
Maximum working cycle (shots/hour):
7200 (±10%)
Frequency:
50/60 Hz
(with machine settings at: 1.2kW 1.3ms 2Hz and ambient room temperature: 25°C/77°F)
Phases:
single
Working temperature:
10°C–40°C
Max. input current:
15 Amps
(50°F–104°F)
Max. noise level:
dBA <70 LwA
Storage temperature:
0°C–60°C
Approx. net weight:
88.2 lbs. (40kg)
(32°F–140°F)
Laser class:
Type 4
Humidity:
30%–90%
Cooling system:
Water and forced air
Maximum altitude:
2000m
Microscope:
10X power (Leica)
For indoor use only
Applicable standards and directives:
The device has been constructed in accordance with the provisions of the directive low voltage (LVD) 2014/35/CE, directive EMC 2014/30/CE
and the following reference standards:
EN60825-1
Safety of laser products
Part 1: Product classification and requirements.
EN61326-1
EMC standard for measurement, control and laboratory use.
EN61010-1
Safety requirements for electrical equipment for measurement, control, and laboratory use.
Intended use
Use the device for the welding of specific metal alloys
.
Only the following alloys may be used
:
•
Gold
•
Silver
•
Platinum
•
Palladium
•
Titanium
•
Steel
•
Cobalt chrome (
CoCr)
The metals
and
alloys listed above must not contain
any
of the metals listed in
the section
"Improper use".
The shielding gas recommended for the welding process is Argon. Use only genuine parts and consumable
materials from
Neutec USA
For technical assistance, please contact Neutec USA Consumable materials should be replaced after use
.
Follow all regulations and safety
instructions
in this
manual
.