Operator’s Handbook
Ca
pi
tol
o:
Use
18
Maintenance
Please read the chapter on
Safety Information
before proceeding
Every maintenance operation, even minor ones for machine parts and the electrical system, requires the use of professionally
qualified personnel with training on the features of the device.
Original spare parts should be used. The use of non-original spare parts releases the Manufacturer from any liability.
Regular inspections
Check the integrity of the laser radiation safety glass on the KG3 viewing window and the leather curtains for hand access to the welding
chamber daily; if they need to be replaced, contact the manufacturer. Using the device with broken glass or without the curtains is DANGEROUS
and can cause health damage. Check the status and the integrity of the safety labels and ID plate every six months, contact the manufacturer if
they are discolored or illegible.
Checking the coolants
The equipment is provided of a cooling system working with bi-distilled water. The water shall be replaced at least every 12 months to avoid
having algae or limestone, which along time may deposit in the cooling pipes or in the LASER pool cavity.
Open up the rear pipes seat and pull out the 2 pipe caps. Pour the water (around 2 lts) into a basin.
Checking the filters
Air filter must be checked every month. Refer to ”routine maintenance” chapter for more ifnormation
Checking the protective glass slide
Verify at least once in a month the state of the glass placed inside of the welding chamber.
Routine Maintenance
Removal of the liquid
Pull the small pipe located underneath the LASER base, remove the cap (see picture); place the basin under the opened pipe and wait the water
tank to be fully emptied (around 2 lts).