background image

9

8

8. Frequenzgänge und Polardiagramme

Frequency Range and Polar Pattern

°

KMS 140

gemessen im freien Schallfeld nach IEC 60268-4
measured in free-field conditions (IEC 60268-4)

7. Technische Daten

KMS 140/150

Akust. Arbeitsweise ........... Druckgradientenempfänger

Richtcharakteristik ..................................... Niere/Hyperniere

Übertragungsbereich ....................................... 20 Hz...20 kHz

Feldübertragungsfaktor

1)

bei 1 kHz ................................................ 15/10 mV/Pa ± 1 dB
mit Vordämpfung ............................................... 4,7/3,1 mV/Pa

Nennimpedanz ............................................................... 50 Ohm

Nennabschlußimpedanz ...................................... 1000 Ohm

Geräuschpegelabstand
CCIR 468-3 ............................................................... 68 dB/66 dB

Ersatzgeräuschpegel
CCIR 468-3 ............................................................... 26 dB/28 dB

Ersatzgeräuschpegel
DIN/IEC 651 ................................................ 16 dB-A/18 dB-A

Grenzschalldruckpegel für

0,5% Klirrfaktor

2)

............................................... 138 dB/142 dB

mit Vordämpfung ............................................. 148 dB/152 dB

Max. Ausgangsspannung dabei ................................. 10 dBu

Phantomspeisespannung
(P48, IEC 1938) ....................................................... 48 V ± 4 V

Stromaufnahme ...................................................................... 2 mA

Erforderlicher Steckverbinder .................................. XLR 3 F

Gewicht .............................................................................. ca. 285 g

Durchmesser ....................................................................... 48 mm

Länge ..................................................................................... 175 mm

1)

 bei 1 kHz an 1 kOhm Nennabschlußimpedanz. 1 Pa   94 dB SPL.

2)

 Klirrfaktor des Mikrophonverstärkers bei einer Eingangsspannung, die der

von der Kapsel beim entsprechenden Schalldruck abgegebenen Spannung
entspricht.

7. Technical Specifications

KMS 140/150

Acoustical oper. principlePressure gradient transducer

Directional pattern ........................... cardioid/hypercardioid

Frequency range ................................................ 20 Hz...20 kHz

Sensitivity

1)

at 1 kHz ................................................... 15/10 mV/Pa ± 1 dB
with preattenuation .......................................... 4.7/3.1 mV/Pa

Rated impedance ......................................................... 50 ohms

Rated load impedance .......................................... 1000 ohms

S/N ratio
CCIR 468-3 ............................................................... 68 dB/66 dB

Equivalent SPL
CCIR 468-3 ............................................................... 26 dB/28 dB

Equivalent SPL
DIN/IEC 651 ................................................ 16 dB-A/18 dB-A

Max. SPL

for less than 0,5% THD

2)

........................... 138 dB/142 dB

with preattenuation ........................................ 148 dB/152 dB

max. output voltage ........................................................ 10 dBu

Phantom powering
(P48, IEC 1938) ......................................................  48 V ± 4 V

Current consumption ........................................................ 2 mA

Matching connector ....................................................... XLR 3 F

Weight ...................................................................... approx. 285 g

Diameter ................................................................................ 48 mm

Length .................................................................................. 175 mm

1)

 at 1 kHz into 1 kOhm rated load impedance. 1 Pa   94 dB SPL.

2)

 THD of microphone amplifier at an input voltage equivalent to the

capsule output at the specified SPL.

Summary of Contents for KMS 140

Page 1: ...Bedienungsanleitung Operating Instructions KMS 140 150 Ollenhauerstr 98 D 13403 Berlin Tel 49 30 41 77 24 0 Fax 49 30 41 77 24 50 Email headoffice neumann com Web www neumann com...

Page 2: ...insprechrichtung ist axial Aufgrund des bei Solistenmikrophonen typischen kur zen Besprechungsabstandes ist der Ba frequenzgang entsprechend dem Naheffekt entzerrt s Frequenz gangkurven Table of Conte...

Page 3: ...3 m 27 0 3 m 27 0 3 m Cat No 06602 Y cable with a 5 pin XLR connector and two 6 3 mm monojacks unbalanced It is used to connect 5 pin XLR outputs of the BS 48 i 2 power supply or the MTX 191 A matrix...

Page 4: ...Powering If a mains power source is not available power can be supplied by one of the units BS 48 i for one mi crophone or BS 48 i 2 for two microphones Both units deliver 48 V 1 V at 5 mA maximum an...

Page 5: ...L nge 175 mm 1 bei 1 kHz an 1 kOhm Nennabschlu impedanz 1 Pa 94 dB SPL 2 Klirrfaktor des Mikrophonverst rkers bei einer Eingangsspannung die der von der Kapsel beim entsprechenden Schalldruck abgegeb...

Page 6: ...ontrolle deren Kosten im Vergleich zu einer aufwendigen Reparatur sehr gering sind 9 Some Remarks on Microphone Maintenance Use the dust cover Microphones not in operation should not be left on the fl...

Page 7: ...krophonaufh ngung Die Elastische Aufh ngung EA 2124 A mt besitzt einen schwenkbaren Gewindeanschlu 5 8 27 Gang mit einem Reduzierst ck zur Verbindung mit 1 2 und 3 8 Ge windezapfen Die Oberfl che ist...

Page 8: ...kHz ca 3 dB D mpfung des Windger usches ca 27 dB gemessen in verwirbelter Luftstr mung der Geschwindigkeit 20 km h erzeugt von einer ger uschlos arbeitenden Windmaschine ohne elektrisches Filter 10 6...

Page 9: ......

Reviews: