Neumann.Berlin KK 104 S Operating Instructions Manual Download Page 3

4

5

KK 104/105 S

1. Brief description

The  KK 104 S  and  KK 105 S  capsule  heads  are  combined  with  the  Sennheiser
SKM 5200/SKM 5000 (N) handheld transmitter to create wireless microphones. These
capsule heads are derived from the Neumann wired vocalist microphones, and fea-
ture the same basic design and the same essential acoustic properties.

The  KK 104 S  capsule  head  has  a  cardioid  directional  characteristic,  while  the
KK 105 S has a supercardioid directional characteristic.

The key features are:

• very clean, open sound reproduction, free of coloration

• very low sensitivity to handling noise

• integrated, highly effective protection against pop noise

• low self-noise

Since vocalist microphones are typically addressed at close range, the bass frequency
response is equalized so as to compensate for the proximity effect (see frequency re-
sponse).

2. Cleaning

The interior assembly can be removed completely to clean the headgrille. First loosen
the 3 axial hexagonal socket screws using the Allen wrench provided.

Important:

Important:

Important:

Important:

Important: When loosening the screws, unscrew each screw only 2

only 2

only 2

only 2

only 2 rotations

rotations

rotations

rotations

rotations. (If the

screws are unscrewed further, this could result in loss of the screws.) Then release the
interior assembly by rotating it 30° counterclockwise, and remove it axially.

Reverse these steps to reinstall the cleaned headgrille: Insert the interior assembly
axially, then rotate it approximately 30° clockwise until it reaches the stop position.
Then tighten the 3 hexago-
nal socket screws using the
Allen wrench provided.

Soap  solution  (standard
dishwashing detergent) can
be used to clean the head-
grille.  After  washing  the

headgrille, rinse it in clean water and then dry it.

In the case of the KK 104 S, the foam insert of the headgrille can be removed sepa-
rately for cleaning.

3. Technical Specifications

KK 104 S

Directional pattern ............................................................................................. Cardioid

Frequency range ....................................................................................... 20 Hz...20 kHz

Equivalent SPL DIN/IEC 651 ............................................................................... 31 dB-A

Equivalent SPL CCIR 468-3 .................................................................................... 42 dB

Sensitivity

1) ....................................................................................

1.7 mV/Pa ± 1 dB   –55.4 dBV

Max. SPL for less than 0.5%/3% THD

2)

....................................................... 148/153 dB

Weight ...................................................................................................................... 120 g

Diameter ................................................................................................................ 48 mm

Length .................................................................................................................... 70 mm

KK 105 S

Directional pattern ................................................................................... Supercardioid

Frequency range ....................................................................................... 20 Hz...20 kHz

Equivalent SPL DIN/IEC 651 ............................................................................... 33 dB-A

Equivalent SPL CCIR 468-3 .................................................................................... 44 dB

Sensitivity

1) ........................................................................................

1.3 mV/Pa ± 1 dB   –58 dBV

Max. SPL for less than 0.5%/3% THD

2)

....................................................... 150/155 dB

Weight ...................................................................................................................... 120 g

Diameter ................................................................................................................ 48 mm

Length .................................................................................................................... 70 mm

1)

At 1 kHz into 100 kOhm rated load impedance. 1 Pa   94 dB SPL.

2)

THD of microphone amplifier at an input voltage equivalent to the capsule output at the specified SPL.

Hexagonal socket
screws

Summary of Contents for KK 104 S

Page 1: ...llenhauerstr 98 13403 berlin germany fon 49 0 30 41 77 24 0 fax 50 headoffice neumann com www neumann com Bedienungsanleitung Operating Instructions Notice d emploi Istruzioni per l uso Instrucciones...

Page 2: ...ine Drehung um 30 entgegen dem Uhrzeigersinn entriegeln und axial herausnehmen Die Montage des gereinigten Korbes erfolgt in umgekehrter Reihenfolge Der Einsatz wird axial eingef hrt und um etwa 30 im...

Page 3: ...ews are unscrewed further this could result in loss of the screws Then release the interior assembly by rotating it 30 counterclockwise and remove it axially Reverse these steps to reinstall the clean...

Page 4: ...structure int rieure en la faisant tourner de 30 dans le sens inverse des aiguilles d une montre puis la retirer dans le sens de l axe Le montage de la grille apr s nettoyage s effectue dans l ordre...

Page 5: ...erdano In seguito ruotare la parte interna di 30 gradi in senso antiorario in modo che possa essere rimossa assialmente Per riposizionare la griglia pulita ripetere in senso inverso gli stessi passagg...

Page 6: ...eada girando 30 en sentido contrario al reloj y sacada axialmente Una vez limpiada el montaje se llevar a cabo en el orden contrario Insertaremos la construcci n interior axialmente y giramos aproxima...

Page 7: ...n av den rengjorda korgen sker i omv nd ordning Innekonstruktionen f rs i axialt och vrids om ca 30 medsols till anslagen Sedan s tts de tre insexkantskru vorna fast med medf ljande nyckel Till reng r...

Page 8: ...in draait kunt u het ontgrendelen en in axiale richting uit de microfoonkop halen Ga in omgekeerde volgorde te werk om de microfoonkop na reiniging weer te monte ren Bevestig het binnenwerk axiaal in...

Page 9: ...y Range and Polar Patterns R ponse en fr quence et diagramme de la directivit Risposta in frequenza e diagrammi polari Caracter sticas de frecuencia y diagramas polares Frekvenskurvor och poldiagram F...

Page 10: ...avec les normes et directives CE applicables Dichiarazione di Conformit Georg Neumann GmbH Berlin dichiara che questa apparecchiatura conforme ai re quisiti standard e alle normative della CE Declara...

Page 11: ...Irrt mer und technische nderungen vorbehalten Errors excepted subject to changes Printed in Germany Publ 03 06 094825 A02...

Reviews: