Important!

 Failure to ensure the correct assembly will

cause leakage of gas.

Important!

 Make sure that the gas supply pressure of

the appliance obeys the recommended values.

Rigid connection:

Carry out connection by using metal rigid pipes (copper
with mechanical end).

Injectors replacement

1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. With a socket spanner 7 remove the injectors and

replace them with the ones which are necessary
for the type of gas you use (see table in "Technical
Information" chapter).

4. Assemble the parts, follow the same procedure

backwards.

5. Replace the rating plate (it is near the gas supply

pipe) with the one for the new type of gas supply.
You can find this plate in the package supplied with
the appliance.

If the supply gas pressure is changeable or different
from the necessary pressure, you must fit an applicable
pressure adjuster on the gas supply pipe.

Adjustment of minimum level

To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-pass screw

position.

A

A) The by-pass screw
• If you change from natural gas G20 20 mbar to liquid

gas, fully tighten the adjustment screw in.

• If you change from liquid gas to natural gas G20 20

mbar, undo the by-pass screw approximately 1/4 of a
turn.

Warning!

 Make sure the flame does not go out

when you quickly turn the knob from the maximum

position to the minimum position.

Electrical connection

• Do not pull the mains cable to disconnect the appli-

ance. Always pull the mains plug.

• The appliance must not be connected with an exten-

sion cable, an adapter or a multiple socket. There is
a risk of fire.

• Do not let the power cable to heat up to a tempera-

ture of more than 90° C. The cable should be guided
by means of clamps fixed to the side of the cabinet,
in order to avoid any contact with the equipment be-
neath the cooktop.

• Make sure that there is access to the mains plug af-

ter the installation.

Electrical Requirements

Permanent electrical installation must agree with the lat-
est I.E.E. Regulations and local Electricity Board regula-
tions. For your own safety the installation must be done
by a qualified electrician (e.g. your local Electricity
Board, or a contractor who is on the roll of the National
Inspection Council for Electrical Installation Contracting
[NICEIC]).

The manufacturer refuses to be held responsi-
ble, if these safety measures are not abided

by.

Supply connections:

This hob has to be connected to 230 — 240 V ( 50 Hz)
electricity supply.

The hob has a terminal block which is marked as
follows:

L

 — Live terminal

N

 — Neutral terminal

 or 

E

 — Earth terminal

Before carrying out the connection, make sure:
1.

The limiter valve and the electrical system can take
the appliance load (see the rating plate)

2.

The supply system is equipped with an efficient
earth connection in compliance with the current
standards and regulations

10

 

Summary of Contents for GH602

Page 1: ...User manual Hob GH602 GB...

Page 2: ...instructions with the appli ance for future reference Children and vulnerable people safety Warning Risk of suffocation injury or permanent disability This appliance can be used by children aged from...

Page 3: ...ecom mend to install a non combustile separation panel under the appliance to prevent access to the bottom Electrical connection Warning Risk of fire and electrical shock All electrical connections mu...

Page 4: ...all on the appliance The surface can be damaged Do not activate the cooking zones with empty cook ware or without cookware Do not put aluminium foil on the appliance Do not let acid liquids for exampl...

Page 5: ...s supply ignition Daily use Warning Refer to the Safety chapters Ignition of the burner Warning Be very careful when you use open fire in kitchen environment Manufacturer decline any responsibility in...

Page 6: ...the flame out turn the knob to the symbol Warning Always turn the flame down or switch it off before you remove the pans from the burner Helpful hints and tips Warning Refer to the Safety chapters En...

Page 7: ...h Removing the dirt 1 Remove immediately melting plastic plastic foil and food containing sugar Stop the appliance and let it cool down be fore you clean limescale rings water rings fat stains shiny m...

Page 8: ...rried out by a registered engi neer the visit from the customer service technician or dealer may not take place free of charge even during the warranty period These data are necessary to help you quic...

Page 9: ...tting room with a volume greater than 20 m but not in a bathroom or shower room The minimum distance combustible material can be fit ted above the hob in line with the edges of the hob is 400 mm If it...

Page 10: ...e flame does not go out when you quickly turn the knob from the maximum position to the minimum position Electrical connection Do not pull the mains cable to disconnect the appli ance Always pull the...

Page 11: ...ith the letter L It must always be con nected to the network phase There must be no cut or stray strands of wire present The cord clamp must be correctly attached to the outer sheath To replace the co...

Page 12: ...ed separately for safety reasons and to let easy remove oven from the unit Technical information Hob dimensions Width 580 mm Length 500 mm Hob recess dimensions Width 550 mm Length 470 mm Heat input R...

Page 13: ...dentified by marking PE PS etc Dis card the packaging materials as household waste at the waste disposal facilities in your municipality GB GREAT BRITAIN Customer Care and Service Standard Guarantee C...

Page 14: ...Serial No Date of Purchase Customer Care Please contact Electrolux Major Appliances Addington Way Luton Bedfordshire LU4 9QQ Contact No 08445 613613 14...

Page 15: ...15...

Page 16: ...397320401 A 232013...

Reviews: