background image

11 

4 TV and AC INSTALLATION 

A TV can be installed above the burner enclosure by following the methods shown below. 

Single-Sided, Left-Corner, Right-Corner and Three-Sided Installations 

 

See-Through and Peninsula Installations 

 

If an air conditioning vent or fan is located near the burner the vent or fan must be positioned to blow 
away from the burner. 

 

m

in

3

0

 in

min. 2 in

m

in

3

0

 in

min. 2 in

Summary of Contents for AA-11-04744

Page 1: ...etely before installing or operating the NetZero PrimeFire Burner NetZero PrimeFire Burner Models AA 11 04744 NZ36B WARNING If the information in these instructions is not followed exactly a fire or e...

Page 2: ...CES AND INSTALLATION 6 3 1 Burner Clearances and Cavity Measurements 6 3 2 Burner Clearances and Cavity Measurements for Multiple Burners 8 3 3 Placing the Burner 9 3 4 Installing Technical Glass 9 3...

Page 3: ...emperatures keep children clothing and furniture away 4 Risk of indoor air pollution use unvented decorative appliance only in well ventilated areas People with breathing problems should consult a phy...

Page 4: ...d ventilation is provided through infiltration The unvented decorative appliance should be installed in a room where at least 200 ft 3 5 7 m3 of air space is provided for each 1 000 BTU per hour of un...

Page 5: ...s Screw Lifting straps M3x15 NZ36B 1 1 1 2 1 2 2 2 2 Optional Equipment Applies to see through peninsula and island installations For information on installing the large glass barrier kits reference t...

Page 6: ...6 1 8 16 36 Ensure that burner flame is positioned a minimum of 40 inches away from curtains flammable materials and other sources of ignition Be aware of drafts Do not place in areas where fans vents...

Page 7: ...p between the material can be left open or insulated with mineral wool Method for creating an air gap behind non combustible finishing material Hardibacker 500 or other non combustible rated cement bo...

Page 8: ...rrangement The C and D dimensions will be calculated from the total length of the burners placed together An example is given below Measurements Burner Model L in A in B in C in D in E in F in G in H...

Page 9: ...click to watch the video instruction https www youtube com watch v b5dETFNTBW4 feature youtu be 3 4 Installing Technical Glass Scan or click to watch the video instruction https www youtube com watch...

Page 10: ...Three Sided Installations Installation Requiring Large Glass Barrier Kit See Through Peninsula and Island Installations For these installations the Large Glass Barrier Kit must be used For additional...

Page 11: ...methods shown below Single Sided Left Corner Right Corner and Three Sided Installations See Through and Peninsula Installations If an air conditioning vent or fan is located near the burner the vent...

Page 12: ...12 5 HOW TO OPERATE THE BURNER 5 1 Components HOT FUEL READY HOT FUEL READY HOT FUEL READY Control LED OFF Control LED ON Control LED Blinking...

Page 13: ...d the button on the pump to start refuelling IV Once the fuel container has been emptied replace it with a full one and start the pump again see point b The pump will stop when the tank is full beep c...

Page 14: ...enabled by default To disable FAST START press and hold ECO for 10 seconds four beeps To enable the function press and hold ECO for 10 seconds two beeps 5 4 Troubleshooting Some alarms are accompanie...

Page 15: ...ly reported to the seller or distributor of the burner Regularly clean the surface of the burner with a soft dry cloth While cleaning please be aware that due to the design of the burner the filament...

Reviews: