17
ArchiTech Cylindrical Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions
15. RECTANGULAR PROXIMITY READER INSTALLATION
The
Rectangular Mounting Plate
IS NOT symmetrical, and therefore does have a "top" and a "bottom". Note the two
Top Tabs
and two
Bottom Tabs
shown in Fig. 15A:
15A. INSTALL THE "RECTANGULAR RUBBER GAS-
KET" AND THE "RECTANGULAR MOUNTING
PLATE"
See Fig. 15A. Place the
Rectangular Rubber Gasket
(with its attached
Rectangular Mounting Plate
) over
the 5/8" diameter thru-hole that was drilled into the
door in step 9C, then secure (
snug-tight only, do not
over-tighten
) using the two Phillips Pan Head screws
appropriate for the door type as follows:
For Metal Doors:
#6-32 x 1/2"
long Type F thread cutting Phil-
lips head (part #SC212);
For Wood Doors:
#6 x 1/2"
long Type A Phillips head (part
#SC265)
Again,
do
NOT
over-tighten these screws; over-
tightening will cause undesired deformation of the
Rubber Gasket
.
15B. RUN THE RECTANGULAR PROXIMITY READER WIRES
From the outside ("unprotected" side) of the door, feed the
Rectangular Proximity Reader
wires (plug sleeves are
orange
and
blue
) fully into the 5/8" diameter thru-hole to the inside ("protected" side) of the door.
Do not pinch
wires
.
FIG. 15A: "RECTANGULAR MOUNTING PLATE" AND THE
ATTACHED "RECTANGULAR RUBBER GASKET"
Rectangular Mounting Plate
Rectangular
Rubber Gasket
Bottom Tab
Bottom Tab
Top Tab
Top Tab
Thru-Hole
RECTANGULAR
FIG. 15B: FEED THE WIRES INTO
THE 5/8" DIAMETER THRU-HOLE