The following tables list facility interfaces, manufacturer's network interface port designations, RENs or service order codes, and network jacks,
This table lists the network trunk interfaces for digital services.
Manufacturer
Port Identifier
Digital Interface Code
(FIC)
Service Order Code
(SOC)
Network Jack
T1/E1 PSTN
04DU9-BN
6.0P & 6.0Y
RJ48
T1/E1 PSTN
04DU9-DN
6.0P & 6.0Y
RJ48
T1/E1 PSTN
04DU9-1KN
6.0P & 6.0Y
RJ48
T1/E1 PSTN
04DU9-1SN
6.0P & 6.0Y
RJ48
Manufacturer
Port Identifier
Digital Interface Code
(FIC)
REN
Network Jack
FXO
02LS2
0.4B
RJ11
FXO
02GS2
0.4B
RJ11
Disruption of the Network
If the UX1000 Unified Exchange disrupts the telephone network, the telephone company can discontinue your service temporarily. If possible,
the telephone company will notify you in advance. If advance notice is not practical, they will notify you as soon as possible. You are also
informed of your right to file a complaint with the FCC.
Telephone Company Facility Changes
The telephone company can make changes in its facilities, equipment, operations, or procedures that can affect the operation of your
equipment. If they do, you should be notified in advance so you have an opportunity to maintain uninterrupted telephone service.
Non-live Voice Equipment
Non-live voice equipment such as music-on-hold devices and recorded announcers for systems must be approved by and registered in
accordance with the ACTA adapted ANSI/TIA-968-B standard, or it must be connected through protective circuitry that is approved by N.E.T. and
registered in accordance with the ACTA adapted ANSI/TIA-968-B standard.
Newly Established Network Area and Exchange Codes
The routing software features allowing user access to the network must recognize newly established network area codes and exchange codes as
they are placed in service.
Failure to upgrade the premises systems or peripheral equipment to recognize the new codes as they are established restricts the customers
and the customer’s employees from gaining access to the network and to these codes.
Equipment with Direct Inward Dialing (DID)
Allowing the equipment to be operated in such a manner as to not provide for proper answer supervision is a violation of Part 68 of the FCC
rules.
Proper answer supervision is when:
This equipment returns answer supervision to the PSTN when DID calls are:
Answered by the called station.
Answered by the attendant.
Routed to a recorded announcement that can be administered by the CPE user.
Routed to a dial prompt.
This equipment returns answer supervision on all DID calls forwarded to the PSTN. Permissible exception are:
A call is unanswered.
A busy tone is received.
A reorder tone is received.
Hearing-Aid Compatibility
Telephones for emergency use and telephones installed in common areas such as lobbies, hospital rooms, elevators, and hotel rooms must
have handsets that are compatible with magnetically coupled hearing aids. Persons who are not in common areas must also be provided with
hearing-aid compatible handsets, if needed.