ASI-IP-GTW User's Manual
Page
66
Table 12. Alarms
Alarm
id
Alarm Severity
level
Description
100
No sync
Critical
No valid ASI input stream detected.
101
ASI bitrate too high
Critical
The ASI input bitrate has exceeded the
configured maximum value.
121
Bitrate regulation in
progress
Filtered
The regulation algorithm is estimating the
incoming bitrate to compensate for the
difference in PCR clocks on the source
encoder and the IP receiver. While this
alarm is active, the output bitrate may be
tuned beyond the limits of the ASI
specifications.
130
Ethernet link down
Critical
No link on Ethernet layer
131 Output
buffer
overflow
Warning
The total bitrate of the ASI input streams is
too high.
140
ARP unresolved
Warning
IP address is not resolved into physical
MAC address.
150
Sequence error
Warning
Analysis of the sequence number of the
RTP layer indicates that IP frames have
been lost or that they have been received
out of order.
151
No data received
Warning
No data received on Ethernet input for
stream
152 FEC
threshold
exceeded
Warning
The frequency of lost frames is higher than
the configured value. Threshold values are
configured per stream.
153 Input
buffer
overflow
Warning
The total bitrate of the IP input streams is
too high.
154
Data lost
Critical
The data stream received for a channel is
incomplete, and if running FEC, the FEC
engine is not able to recover all the lost
frames.
155
No lock
Critical
The IP receive channel is not able to find
an initial bitrate for the data received.
156
MIP not present
Warning
No MIP frames are received.
157
Too low latency for
FEC
Warning
The preferred latency is set lower than the
latency required by the incoming stream.
160 SNTP
server
unreachable
Warning
Unit is not receiving answers from the
SNTP server.
161 Too
high
temperature
Warning
Internal temperature of unit is too high.
162
Defective fan
Warning
One or both of the fans are not spinning.
200
No GPS 1PPS
reference signal
Warning
The 1PPS reference signal is lost. (The
regulator has however not lost
synchronization)
201
Lost GPS 1PPS
synchronization
Critical
The clock synchronization mechanism has
been resynchronized due to too large
phase error.