Permit other device to join
Z809B is featured to be a router in the network. It permits other devices to join the network.
In normal operation, by default the router device Z809B does not permit any device to join
to the network to protect the network from unexpected or unauthorized join attempt. You
will need to open up the permit-join on Z809B or on other router device to allow new
devices (a router or an end device) to join.
Operation:
1.
Short press the binding key once
.
2. The permit join is now enabled for 60 seconds and the
green
network indicator will
flash 60 times.
3. Z809B waits the new device to join in automatically. Please note that the maximum
waiting time to join is 60 seconds. Repeat the process if you missed the 60 seconds
period.
Power Consumption Reporting
When the load is attached to the device, the embedded meter reads the supplied current
drawn overtime. Z809B reports the readings to a
paired target
device normally an in-home
display or consumption data logger. Ensure that you go through
Consumption reporting
and also
Configure reporting time interval
described in
ZiG-BUTLER
page, otherwise
Z809B will not sent consumption reading properly when misconfigured
.
Z809B can report
the consumption reading to Netvox’s ZiG-BUTLER or to any 3
rd
party in-home display.
If
target device pairing
is
not
done (refer to
Consumption reporting in ZiG-BUTLER
section
)
,
Z809B will, by default, report at time interval of 180s minimum or 300s maximum.
The reportable change is 2048.
Units
Power drawn overtime is measured. Current
(unit mA)
, Voltage
(unit V)
, Power
(unit kW)
and Energy
(unit kWh)
. Z809B stores a new value read and updates such value and
clears up the previous. User may want to return the reading back to zero when wish. Refer
to
Resetting Power Consumption Summation
section bellow.
Possible reading losses
Z809B stores the reading to the memory at every 30 seconds and 15 seconds for some
Z809B. If power is disconnected from power source, the reading in the temporal buffer will
not be recorded.
Reading accuracy
If the output current is above 50mA, the reading accuracy of current, voltage, power and
energy is ±1%. Current detection range is between 50mA to 3A.