Configuration setting
As mentioned in
How to use Z809B
section, when the Off button is press twice and then
press On button once, Z809B will stay Off. This is to prevent from accidentally turning the
device on. This is a factory default setting. Programmer may, however, overwrite this
setting permanently by setting On Level attribute to any value between 0x00 to 0xFE.
0xFF
is the factory default.
Installation Notes:
1
、
Z809B stores power consumption data once every 30 seconds, thus the power
data of last 30 seconds before power-fail could probably be lost.
(
24C01, 30
seconds; 24C02, 15 seconds….
)
2、
Z809B is designed as a light dimmer. No other electric appliances but dimmable
lights can be attached to this product.
3、
Z809B is not a waterproof product, use it indoor only.
4
、
Load Protection: The current is over 3A → it will be off-load in 2 seconds.
5
、
After it is off-load, the Bit1 (Current OverLoad) of the parameter ACAlarmsMask
will be checked:
Bit1 (Current OverLoad) is 1
→
it sends the alarm message;
Bit1 (Current OverLoad) is 0
→
it doesn
’
t send the alarm message
When it sends the alarm message
→
AlarmCluster = 0x0B04; AlarmCode = 0xF0;
indicator flashes
10 times
.
6
、
Z809B is using PWM dimming with leading Triac technology. Please DO NOT use
improper light/lamp/device or it may cause damages. For example, regular LED
lamp which does not support dimmer features, gas-discharge lamp, home
appliance, computer, or on-off relay is not supported.
7
、
The maximum electrical load of Z809B:
a. Resistive Load (incandescent light bulb): 3A/600W.
b. Dimmable fluorescent lamp or dimmable LED lamp: 100W. Parallel
connection is not recommended.
c. DO NOT connect coil transformer for dimming.