5
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according
to Min Interval.
Low Battery Voltage Threshold
Low Voltage
2.4 V
5.
Data Report
After power on, the device will immediately send a version packet report and a data report including the voltage.
The device sends data according to the default configuration before any other configuring.
Default setting:
Report MaxTime: 3600s (1H)
Report MinTime: 3600s (1H)
Battery Voltage Change: 0x01 (0.1V)
(If there are special customized shipments, the settings will be changed according to customer’s requirement.)
Status change
:
Press: Report: 1.
Not pressed: Report: 0.
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
The data parsing that is reported by the device please refer to Netvox LoraWAN Application Command document and
http://loraresolver.netvoxcloud.com:8888/page/index
Report configuration and sending period are as following:
Min Interval
(Unit: second)
Max Interval
(Unit: second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval