Summary of Contents for RB02B

Page 1: ...d This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole o...

Page 2: ...2 3 Main Feature 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 6 5 3 Example of Button Pressing 7 5 4 Example for MinTime MaxTime logic 8 6 Instal...

Page 3: ...low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wire...

Page 4: ...e configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low...

Page 5: ...fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fai...

Page 6: ...customized shipments the settings will be changed according to customer s requirement Status change Press Report 1 Not pressed Report 0 Note 1 The cycle of the device sending the data report is accor...

Page 7: ...e Report Type NetvoxPayLoadData RB02B 0xA6 0x01 Battery 1Byte unit 0 1V Key1Trigger 1Byte 0x00_NoTrigger 0x01_Trigger Key2Trigger 1Byte 0x00_NoTrigger 0x01_Trigger Reserved 5Bytes fixed 0x00 Example o...

Page 8: ...Configure RB02B report parameters MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 01A6003C003C0100000000 Device Return 81A6000000000000000000 Configuration success 81A6010000000000000000 Config...

Page 9: ...vice Return 8100 Configuration success 8101 Configuration failure 2 Read RB02B device parameter Downlink 02 Device Return 820A device current parameter ButtonPressTime can be set to 255 at most 5 4 Ex...

Page 10: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Page 11: ...paste The middle part of the 3M rubber pad the part with the red frame in the figure below is where the label is attached to the device Please remove the rubber pad that has been cut Do not install th...

Page 12: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...