RA07W has the function of the power-down saving the memory of network-joining 

information. This function acquiesces in turn off, that is, it will rejoin every time when it is 

power on. If the device is turned on by the ResumeNetOnOff command, the last 

network-joining information will be recorded when every time it is power on. (including 

saving the network address information that it is assigned, etc.) If users want to join a new 

network, the device needs to perform the factory setting, and it will not rejoin the last network. 

 

Operation Method 

1.

 

Press and hold the binding button for 5 seconds and then release 

(release the binding button when the LED flashes), and the LED will flash 20 times. 

2.  The device automatically restarts to rejoin the network. 

 

 

 

6.

 

Data Report 

 

After power on, the device will immediately send a version packet report and a data report. 

The device sends data according to the default configuration before any other configuring. 

 

Default Setting: 

MaxTime = 3600s 

MinTime = 3600s 

If there is no leakage, it will report once every 3600s. 

If the leakage change is greater than 2dm, the leakage information will be reported immediately. 

The reported data of the device is the situation of the liquid leakage. 

     

Water Leak Detection: 

(1) Before usage, the sensor length must be set through the instruction.    (Unit: dm.) 

(2) The accuracy of the device is expressed as ± (Length of detection line*0.5%+0.5m). 

(3) When the vertical surface of the leaking sensor is submerged by water, and the horizontal surface exceeds 5cm, 

the device will detect the leaking state, locate the specific position of the leakage, and immediately report the data to 

the gateway. 

*The current sampling cycle is 1s.   

The positioning data may be deviated when just soaked in water, and then the value will stabilize after 5s. 

 

The device reported data parsing please refer to 

Netvox LoraWAN Application Command document

 and 

Netvox Lora Command     

Resolver

 

http://www.netvox.com.cn:8888/page/index

 

 

 

Summary of Contents for RA07W

Page 1: ...Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Application 3 5 Set Up Instruction 4 6 Data Report 5 7 Installation 8 8 Important Maintenance Instruction 10 ...

Page 3: ...tion methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti interference ability and so on LoRa...

Page 4: ...position of the leakage detection line Locate the leakage position Simple operation and setting 4 Application Data center and computer room Leakage monitoring in basement Water pipe leakage detection Ship bilge monitoring Archives Warehouse Other occasions need to be detected whether there is the water leakage or are more sensitive to water leakage Indicator Function Key ...

Page 5: ...etwork The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not in the factory setting Turn on the device to search the previous network The green indicator keeps on for 5 seconds success The green indicator remains off fail Fail to Join the Network Suggest checking the device registration information on the gateway or consulting your platf...

Page 6: ...port The device sends data according to the default configuration before any other configuring Default Setting MaxTime 3600s MinTime 3600s If there is no leakage it will report once every 3600s If the leakage change is greater than 2dm the leakage information will be reported immediately The reported data of the device is the situation of the liquid leakage Water Leak Detection 1 Before usage the ...

Page 7: ...810C010000000000000000 Configuration failure 2 Read RA07W device parameter Downlink 020C000000000000000000 Device return 820C0E100E100000000000 device current parameter Description Device Cmd ID Device Type NetvoxPayLoadData ConfigReport Req RA07W 0x01 0x0C MinTime 2bytes Unit s MaxTime 2bytes Unit s Reserved 5Bytes Fixed 0x00 ConfigReport Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 Re...

Page 8: ...9Bytes Fixed 0x00 GetSensorPara Rsp 0x84 LineLength 2Bytes Unit 10cm Sensitivity 1Byte Hihg_0x00 Mid_0x 01 Low_0x02 Reserved 6Bytes Fixed 0x00 1 Configure RA07W Length od Line 70dm 2 bytes decimeter Sensitivity 00 1 byte 00 is the most sensitive Downlink 030C004600000000000000 Device returns 830C000000000000000000 Configuration success 830C010000000000000000 Configuration failure 2 Read RA07W devi...

Page 9: ... 100 meters Water Detection Alarm It is recommended that the length of the line is soaked in water greater than 5cm and the depth of the line is greater than 2mm refer to the installation diagram Alarm time immediately report within 10 seconds The length of the water line has been set via the main unit before shipping If the rope need to be manually wired the length of the line must be set via the...

Page 10: ...ference susceptible to damage cable damp to false alarm Note The installation position of the water line should be far away from high temperature fire strong magnetic fields and humid and dusty environments Take care to avoid all kinds of sharp objects from scratching the cable sheath RA07W Report time real time within 10 seconds Fixed hook 检测线 5cm Detection wire Soaking depth 2mm Soaking water 5c...

Page 11: ...l form inside which will destroy the board Do not throw knock or shake the device Treating equipment roughly can destroy internal circuit boards and delicate structures Do not wash with strong chemicals detergents or strong detergents Do not paint the device Smudges can make debris block detachable parts up and affect normal operation Do not throw the battery into the fire to prevent the battery f...

Reviews: