10 

7. Important Maintenance Instruction

 

Kindly pay attention to the following in order to achieve the best maintenance of the product: 

• Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets 

wet, please dry it completely. 

• Do not use or store the device in dusty or dirty environment. It might damage its detachable parts and electronic components. 

• Do not store the device under excessive heat condition. High temperature can shorten the life of electronic devices, destroy 

batteries, and deform or melt some plastic parts. 

• Do not store the device in places that are too cold. Otherwise, when the temperature rises to normal temperature, moisture will 

form inside, which will destroy the board. 

• Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate 

structures. 

• Do not clean the device with strong chemicals, detergents or strong detergents. 

• Do not apply the device with paint. Smudges might block in the device and affect the operation. 

• Do not throw the battery into the fire, or the battery will explode. Damaged batteries may also explode. 

 

All of the above applies to your device, battery and accessories. If any device is not working properly, please take it to the nearest 

authorized service facility for repair. 

 

Summary of Contents for R816B

Page 1: ...Monitoring US type R816B User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Page 2: ...2 2 Appearance 3 3 Main Characteristic 3 4 Operation 4 5 Data Report 5 5 1 Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 7 5 3 Example for MinTime MaxTime logic 8 6 Product Installation 9 7 Important Maintenance Instruction 10 ...

Page 3: ...wireless technology LoRa is a wireless communication technology dedicated to long distance low power consumption Its spread spectrum modulation method greatly increases the communication distance compared with other communication methods and can be widely used in long distance low rate IoT wireless communication fields in various occasions Such as automatic meter reading building automation equipm...

Page 4: ...er supply Simple operation and setting Compatible with LoRaWANTM Class C Frequency hopping spread spectrum Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Over current alarm Automatically disconnect the load due to over current Switch Indicator Network Indicator Switch Button Socket 1 Socket 2 Factory Restoring Key inside ...

Page 5: ...device verification information on the gateway or consult your platform server provider Function Key Press and hold the factory restoring key for 5 seconds Restore to factory setting The network indicator flashes for 10 times success The network indicator remains off fail Press and hold the factory restoring key for 10 seconds The network indicator flashes once when the button is pressed for 5s an...

Page 6: ... done Default setting MaxTime 0x0384 900s MinTime 0x0002 2s Mintime is recommended to set by default 2 seconds Need to control to reduce frequent Report recommendations by adjusting reportchange and Max Interval Current Change 0x0064 100mA Power Change 0x0014 20W Note 1 The device reports the ON OFF status energy over current alarm first and after 10 seconds reports the voltage current and power 2...

Page 7: ...LoadData 0x01 0x73 0x01 OnOff 1Byte OFF_0x00 ON_0x01 Energy 4Bytes unit 1wh OverCurrentAlarm 1Byte 0 noalarm 1 alarm 1 DashCurrentAlarm 1Byte 0 noalarm 1 alarm 2 PowerOffAlarm 1Byte 0 noalarm 1 alarm 0x02 Vol 2Bytes Unit 1V Current 2Bytes Unit 1mA Power 2Bytes Unit 1W Reserved 2Bytes fixed 0x00 1 R816B does not support Dash Current Alarm 2 R816B does not support Power Off Alarm First uplink report...

Page 8: ...d 0x00 Read CurrentStatus 0x94 Reserved 9Bytes Fixed 0x00 Config ReportReq 0x01 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2byte Unit 1mA PowerChange 2byte Unit 1W Reserved 1Byte Fixed 0x00 Config ReportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Cur...

Page 9: ...3 Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour PowerChange 2W MaxTime MaxTime MinTime MinTime 0H 1H 2H Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless PowerChange value Example 2 based on MinTime 15 Minutes MaxTime 1 Hour PowerChange 2W MaxTime MinTime MinTime MinTime MinTime 0H 15th M 30th M 45th M 1H 2H Collects...

Page 10: ...al time It is recommended to use the default 2 seconds If users need to control frequent report recommendations to adjust ReportableChange and MaxTime 3 After the device sends a packet regardless of whether the data has changed such as pressing a button or the maximum time is due another MinTime MaxTime calculation cycle is initiated 6 Product Installation This product does not have a waterproof f...

Page 11: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...